摘要
为了更好地对YY 0709—2009中的视觉报警和听觉报警信号进行完整、科学和高效地检测,分析了YY0709—2009《医用电气设备第1-8部分:安全通用要求并列标准:通用要求,医用电气设备和医用电气系统中报警系统的测试和指南》标准的测试方法,并结合检测要求对各种检测方法的优缺点进行了分析,最后给出了推荐的检测方法。
The testing methods involved in YY 0709--2009 Medical electrical equipment - Part 1-8: General requirements for basic sofety -Collateral Standard: General requirements, tests and guidance far alarm systems in medical electrical equip- ment and medical electrical systems are analyzed, in order that the testing for visual signal and audible signal can be executed effectively. Some method is proposed after comparing the advantages and disadvantages of the testing methods. [Chinese Medi- cal Equipment Journal, 2014,35 (2) : 125-126,162]
出处
《医疗卫生装备》
CAS
2014年第2期125-126,162,共3页
Chinese Medical Equipment Journal
基金
国家科技支撑计划项目(2012BAI22B04)