期刊文献+

高清能谱CT在骨科患者术后检查中的应用 被引量:2

Application of high definition spectral CT in checking patients underwent orthopedic surgery
下载PDF
导出
摘要 目的探讨高清能谱CT扫描(GSI CT扫描)在骨科患者术后检查中的应用,同时研究能谱扫描图像与普通CT扫描图像的区别。方法选取6例人工关节和10例骨折金属固定术后随访复查的患者行能谱CT扫描。再应用GSI Viewer软件进行分析,金属伪影去除处理和三维重组,以原始图像为参照,对图像质量进行比较,观察GSI图像对骨折钢板内固定术及人工关节的显示效果。结果高清能谱CT扫描图像较常规CT扫描图像的金属伪影明显减少,能够更清晰地显示人工关节的功能状况、骨折复位和内固定术的修复效果。结论高清能谱CT扫描,GSI在高的KeV区,可有效消除金属植入物伪影和射线束硬化伪影,最佳成像区间为100~140 KeV。利用GSI的合理区间可清晰显示术后的细微结构,图像质量较高。 [ Objective ] To investigate the application of High Definition Spectral CT scan(GSI CT scan) in checking patients underwent orthopedic surgery, and research on the scanning image difference between High Definition Energy Spectrum CT and Conventional CT. [ Methods ] Follow-up 6 patients with joint prosthesis and 10 cases of fracture of metal fixation selected and underwent Energy Spectrum CT examination.. Process the data by GSI Viewer software, avoiding the metal artifact, reconstructing with three-dimensional; Comparative the display quality of anatomical plate fixation and joint prosthesis GSI image. [ Resluts ] Metal artifact significantly reduced in High Definition Spectral CT, more clearly show the function of joint prosthesis, and the effects of fracture reset and internal fixation. [ Conclusion ] Metal artifact and beam-hardening can effectively removed by spectral CT when GSI in the high KeV region, the best imaging interval is 100-140keV. The high quality image can clearly show the fine structure of postoperative by using GSI reasonable interval.
作者 吴祥才
出处 《中国医学工程》 2014年第1期3-4,共2页 China Medical Engineering
关键词 能谱CT 伪影 图像质量 内固定术 spectral CT artifacts image quality internal fixation
  • 相关文献

参考文献6

二级参考文献36

  • 1王学礼.医用CT图像常见伪影成因及矫正分析[J].CT理论与应用研究(中英文),2004,13(3):1-8. 被引量:22
  • 2王积慧,冯毅,刘乃丰.多层螺旋CT冠脉成像技术及其临床应用进展[J].心血管病学进展,2005,26(3):227-230. 被引量:5
  • 3石明国,张振荣,尤志军,郑敏文.CT成像技术的发展[J].中国医学装备,2007,4(4):56-60. 被引量:24
  • 4Matsumoto K, Jinzaki M, Tanami Y, et al. Virtual monochromatic spectral imaging with fast kilovohage switching: improved image quality as compared with that obtained with conventional 120 kVp CT. Radiology, 2011 ,In press.
  • 5Lv P, Lin XZ, Li J, et al. Differentiation of small hepatic hemangioma from small hepatocellular carcinoma: recently introduced soectral CT method. Radioloav. 2011. In nress.
  • 6Lin XZ, Miao F, Li JY, et al. High-definition CT gemstone spectral imaging of the brain: initial results of selecting optimal monochromatic image for beam-hardening artifacts and image noise reduction. J Comput Assist Tomogr, 2011, 35:294-297.
  • 7Zhao LQ, He W, Li JY, et al. Improving image quality in portal venography with spectral CT imaging. Eur J Radiol, 2011, In press.
  • 8Feuerlein S, Roessl E, Proksa R, et al. Muhienergy photoncounting K-edge imaging: potential for improved luminal depiction in vascular imaging. Radiology, 2008, 249 : 1010-1016.
  • 9Pan D, Roessl E, Schlomka JP,et al. Computed Tomography in color: nanok-enhanced spectral CT molecular imaging. Angew Chem Int Ed Engl,2010, 49:9635-9639.
  • 10Cormode DP, Roessl E, Thran A, et al. Atherosclerotic plaque composition: analysis with multicolor CT and targeted gold nanoparticles. Radiology, 2010, 256:774-782.

共引文献393

同被引文献9

引证文献2

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部