摘要 目的评估CT导引结合SPECT/CT穿刺活检对胸部病变的诊断价值。方法回顾性研究CT导引结合SPECT/CT经皮穿刺活检胸部病变34例,活检部位包括肺部30例,胸壁4例,使用18G^20G穿刺针作穿刺抽吸活检。结果穿刺活检成功率100%,穿刺活检诊断为恶性病变16例,良性病变15例。假阴性3例,穿刺活检正确率91.1%。并发症为轻度气胸(4例)。结论 CT导引结合SPECT/CT经皮细针穿刺活检胸部病变是安全可行的诊断方法。 Objective To evaluate the diagnostic value of CT guided percutaneous aspiration biopsy combined with SPECT/CT in thoracic lesions. Methods 34 patients of the thoracic lesions who underwent CT guided percutaneous fine needle aspiration biopsy combined with SPECT/CT were retrospectively reviewed. The sites of CT guided biopsy in 34 patients included the lung (n=30) and the chest wall (n=4)using CT guided percutaneous FANB with 18 -20 gauge needle. Results All lesions were safely accessible with accuracy rate of 100%. The biopsies revealed malignancy in 16 cases, benignity in 15 cases, and false negative in 3 cases. The accuracy of diagnosis was 91.1%. The complication with slight pneumothorax was occurred in 4 cases. Conclusion CT guided aspiration biopsy combined with SPECT/CT is a safe and effective method in diagnosis and differential diagnosis of thoracic lesions.
出处 《临床放射学杂志》 CSCD 北大核心 2014年第3期430-432,共3页 Journal of Clinical Radiology
关键词 放射学 活组织检查 胸部 放射性核素显像 单光子 发射型计算机 体层摄影术 Radiology Biopsy thoracic Radionuclide imaging Single-photon Emission-computed Tomography
  • 相关文献

参考文献6

二级参考文献37

  • 1张雪哲,曲凤宏.CT导引下胸部经皮细针穿刺活检的临床应用[J].中华放射学杂志,1989,23(1):47-48. 被引量:86
  • 2丁其勇,滑炎卿,管一晖,赵军,张国桢.PET和PET/CT对孤立性肺结节的对照研究[J].中华核医学杂志,2005,25(5):261-263. 被引量:38
  • 3陈虞梅,黄钢,孙晓光,刘建军,施一平,万良荣.PET标准化摄取值在肺癌诊断中的价值及其影响因素的探讨[J].核技术,2007,30(1):65-69. 被引量:10
  • 4姚稚明,屈婉莹,刘甫庚,韩丽君,于治国,李伟,赵波沣,朱明,张建飞.^(18)F-FDG PET/CT双时相显像对孤立性肺结节的诊断价值[J].中华核医学杂志,2007,27(1):5-7. 被引量:22
  • 5Even-Sapir E, Keidar Z, Bar-Shalom R. Hybrid imaging ( SPECT/ CT and PET/CT) --improving. the diagnostic accuracy of function- al/metabolic and anatomic imaging. Semin Nucl Med, 2009, 39 : 264-275.
  • 6Brandon D, Alazraki A, Halkar RK, et al. The role of singh-pho- ton emission computed tomography and SPECT/computed tomo- graphy in oncologic imaging. Semin Oncol, 2011, 38: 87-108.
  • 7Mariani G, Bruselli L, Kuwert T, et al. A review on the clinical uses of SPECT/CT. Eur J Nucl Med Mol Imaging, 2010, 37: 1959- 1985.
  • 8Seo Y, Mad C, Hasegawa BH. Technological development and ad- vances in single-photon emission computed tomography/computed tomography. Semin Nuel Med, 2008, 38: 177-198.
  • 9Buck AK, Nekolla S, Ziegler S, et al. SPECT/CT. J Nucl Med, 2008, 49: 1305-1319.
  • 10Alberini JL, Edeline V, Giraudet AL, et al. Single photon emis- sion tomography/computed tomography (SPET/CT) and positron emission tomography/computed tomography (PET/CT) to image cancer. J Surg Oncol, 2011, 103: 602-606.

共引文献159

同被引文献11

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部