低浓度对比剂在冠状动脉CTA检查中的可行性研究 被引量:17

Feasibility of low concentration contrast medium in coronary CT angiography
下载PDF
导出
摘要 目的:探讨低浓度碘对比剂(270 mgI/mL)配合低管电压在冠状动脉CTA检查中的可行性。材料与方法:将90例行冠状动脉CTA检查的患者随机分为A组和B组。A组60例应用270 mgI/mL碘对比剂同时使用迭代算法重建,再将A组根据体质量指数(BMI)分为A1组(25例)及A2组(35例),A1组(BMI<24 kg/m2)管电压为80 kV,A2组(BMI≥24 kg/m2)管电压为100 kV;B组30例应用370 mgI/mL碘对比剂,120 kV管电压。两组均采用前瞻性心电门控扫描。记录扫描辐射剂量,并对图像质量进行主、客观分析。结果:平均有效辐射剂量(ED)A1组为(2.00±0.56)mSv,A2组为(2.35±0.74)mSv,B组为(3.98±1.78)mSv,A1组与B组间及A2组与B组间均有统计学差异(t值分别为-5.34和-4.95,P<0.05)。图像质量方面,A1组与B组间及A2组与B组间主观评价优秀率无统计学差异(χ2值分别为1.10和2.04,P值均>0.05);客观评价图像噪声(SD)、信噪比(SNR)、对比噪声比(CNR)亦均无统计学差异。结论:应用尽可能低浓度的碘对比剂(270 mgI/mL)配合低管电压在冠状动脉CTA检查中是可行的,超重人群(BMI≥24 kg/m2)亦可应用,同时显著的降低了辐射剂量和碘注射量。 Objective: To explore the feasibility of using low concentration contrast medium(270 mgI/mL) with the low tube voltage in coronary artery CTA. Materials and Methods: Ninty patients with coronary CTA examination were divided into group A and group B randomly. Group A (n=60) used contrast medium of 270 mgI/mL with sinogram-affirmed iterative reconstruction(SAFIRE). Group A was further divided into group Al(n=25) and A2(n=35) according to body mass index(BMI). Group Al(BMI〈24 kg/m2) 80 kV was used for scanning, group A2(BMI≥24 kg/m2) 100 kV. The concentration of contrast medium and the tube voltage of group B (n=30) were 370 mgI/mL and 120 kV. All groups were scanned in prospective ECG-trigger gated. Radiation dose was recorded and image quality was analysed subjectively and objectively. Results: The effective dose (ED) of group A1, A2 and B were (2.00±0.56)mSv, (2.35±0.74)mSv and (3.98±1.78)mSv respectively, between group A1 and B, group A2 and B there were statistically significant(t=-5.34 and -4.95, P〈0.05). In image quality, there were no statistical differences between each groups in the excellent rate (x2=l.10 and 2.04, P〉0.05). The SD, SNR and CNR of images also showed no sta- tistical differences by objectively evaluated. Conclusion: Using low concentration contrast medium (270 mgI/mL) with low tube voltage in coronary artery CTA is feasible, especially in overweight(BMI≥24 kg/m2) population. At the same time, the radiation dose and concentration of iodine injection are reduced significantly.
出处 《中国临床医学影像杂志》 CAS 2014年第3期172-175,共4页 Journal of China Clinic Medical Imaging
关键词 冠状动脉疾病 体层摄影术 X线计算机 冠状血管造影术 Coronary disease Tomography, X-ray computed Coronary angiography
  • 相关文献

参考文献8

  • 1Einstein AJ, Moser KW, Thompson RC, et al. Radiation dose to patients from cardiac diagnostic imaging[J]. Circulation, 2007, 116 (11): 1290-1305.
  • 2Austen WG, Edwards JE, Frye RL, et al. A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association [J]. Circulation, 1975, 51(4 Suppl): 5-40.
  • 3Einstein AJ, Henzlova MJ, Rajagopalan S. Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J]. JAMA, 2007, 298 (3): 317- 323.
  • 4崔燕海,黄美萍,梁长虹,刘辉,周涛,刘其顺.64层螺旋CT冠脉CTA对比剂注射方案优化[J].中国医学影像技术,2008,24(3):374-377. 被引量:30
  • 5Leber A W, Becker A, Knez A, et al. Accuracy of 64 -slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound[J]. J Am Coll Cardiol, 2006, 47(3): 672- 677.
  • 6Huda W, Scalzetti EM, Levin G. Technique factors and image quality as functions of patient weight at abdominal CT [J]. Radiology, 2000, 217(2): 430-435.
  • 7Baker ME, Dong F, Primak A, et al. Contrast-to-noise ratio and low -contrast object resolution on full - and low -dose MDCT: SAFIRE versus filtered back projection in a low-contrast object phantom and in the liver[J]. AJR, 2012, 199(1): 8-18.
  • 8徐磊,晏子旭,张兆琪,范占明,吕飙,于薇.双源CT低剂量前瞻性心电触发序列扫描在冠状动脉血管成像的应用[J].中华放射学杂志,2009,43(7):700-703. 被引量:50

二级参考文献20

  • 1孟冷,张兆琪,吕飙.64层螺旋CT在冠状动脉疾病诊断中的价值[J].中华放射学杂志,2006,40(8):792-796. 被引量:129
  • 2Dill T,Deetjen A,Ekinci O,etal.Radiation dose exposure in muhislice computed tomngraphy of the coronaries incomparison with conventional coronary angiography,Int J Cardiol,2008,124:307-311.
  • 3Coles DR,Smail MA,Negus IS,et al.Comparison of radiation doses from multislice computedtomography coronary angiography and conventional diagnostic angiography.J Am CoilCardiol,2006,47:1840-1845.
  • 4Raff GL,Gallngher MJ,O'Neill WW,et al.Dingnostic accuracy of noninvasive coronaryangingraphy using 64-slice spiral computed tomography.J Am Coil Cardiol,2005,46:552-557.
  • 5McCollough CH,Primak AN,Saba O,et al.Dose performance of a 64-channel dual-source CTscanner.Radiology,2007,243:775-784.
  • 6Einstein AJ,Henzlova MJ,Rajagopalan S.Estimating risk of cancer associated withradiation exposure from 64-slice computed tomography coronaryangiography.JAMA,2007,298:317-323.
  • 7Abada HT,Larchez C,Daoud B,et al.MDCT of the coronary arteries:feasibility of low-doseCT with ECG-pulsed tube current modulation to reduce radiationdose.AJR,2006,186:S387-S390.
  • 8Austen WG,Edwards JE,Frye RL,et al.A reporting system on patients evaluated forcoronary artery disease.Report of the Ad Hoe Committee for Grading of Coronary ArteryDisease,Council on Cardiovascular Surgery,American Heart Association.Circulation,1975,51(4 Suppl):5-40.
  • 9Bax JJ,Schuijf JD.Which patients should be referred for noninvasive angiography withmuhi-slice CT? Int J Cardiol,2007,114:1-3.
  • 10Brenner DJ,Hall EJ.Computed tomography:an increasing source of radiation exposure.NEngl J Mad,2007,357:2277-2284.

共引文献78

同被引文献149

  • 1Patricia Carrascosa,Gastón A Rodriguez-Granillo,Carlos Capuay,Alejandro Deviggiano.Low-dose CT coronary angiography using iterative reconstruction with a 256-slice CT scanner[J].World Journal of Cardiology,2013,5(10):382-386. 被引量:2
  • 2邱建星,王继琛,孙晓伟,高莉,秦乃姗,王仪生,蒋学祥.64层螺旋CT评估冠状动脉粥样硬化病变——与血管内超声的对照研究[J].中国医学影像技术,2006,22(10):1456-1459. 被引量:24
  • 3蒋学祥,邱建星,刘剑,王继琛,高莉,孙晓伟,秦乃姗.64层螺旋CT评估冠状动脉狭窄的准确性——与传统冠状动脉造影对照研究[J].中国医学影像技术,2006,22(10):1472-1476. 被引量:49
  • 4张龙江,祁吉.对比剂肾病:一个值得关注的问题[J].中华放射学杂志,2007,41(8):882-884. 被引量:69
  • 5杨根仁,柴春华,肖圣祥,等.迭代重建在256层CT前瞻性心电门控冠状动脉成像中的应用[C].2012年浙江省放射学术年会论文集,2012.
  • 6Bettencourt N,Chiribiri A,Schuster A,et al.Direct comparison of cardiac magnetic resonance and multidetector computed tomography stress-rest perfusion imaging for detection of coronary artery disease[J].J Am College Cardiol,2013,61(10):1099-1107.
  • 7Kiriyama T,Toba M,Fukushima Y,et al.Discordance between the morphological and physiological information of 64-slice MSCT coronary angiography and myocardial perfusion imaging in patients with intermediate to high probability of coronary artery disease[J].Circulation J,2011,75(7):1670-1677.
  • 8Stacul F,van der Molen A J,Reimer P,et al. Contrast induced ne phropathy: updated ESUR Contrast Media Safety Committee guidelines[J]. Eur Radiol,2011,21(12) :2527-2541.
  • 9Hur G, Hong S W,Kim S Y,et al. Uniform iamge quality achieved by tube current modulation using SD of attenuation in coronary CT angiography[J]. AJR,2007,189(1) :188-196.
  • 10AsiI A,Epstein M. Prevention of radiocontrast-induced nephropa thy[J]. Am J Kidney Dis, 2004,44 ( 1 ) : 12 - 24.

引证文献17

二级引证文献69

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部