期刊文献+

Addition of hydrogen peroxide for the simultaneous control of bromate and odor during advanced drinking water treatment using ozone 被引量:15

Addition of hydrogen peroxide for the simultaneous control of bromate and odor during advanced drinking water treatment using ozone
原文传递
导出
摘要 Complete removal of the characteristic septic/swampy odor from Huangpu River source water could only be achieved under an ozone dose as high as 4.0 mg/L in an ozone-biological activated carbon (O3- BAC) process, which would lead to the production of high concentrations of carcinogenic bromate due to the high bromide content. This study investigated the possibility of simultaneous control of bromate and the septic/swampy odor by adding H2O2 prior to the O3-BAC process for the treatment of Huangpu River water. H2O2 addition could reduce the bromate concentration effectively at an H2O2/O3 (g/g) ratio of 0.5 or higher. At the same time, the septic/swampy odor removal was enhanced by the addition of H2O2, although optimization of the H2O2/O3 ratio was required for each ozone dose. At an ozone dose of 2.0 mg/L, the odor was removed completely at an H2O2/O3 ratio of 0.5. The results indicated that H2O2 application at a suitable dose could enhance the removal of the septic/swampy odor while suppressing the formation of bromate during ozonation of Huangpu River source water. Complete removal of the characteristic septic/swampy odor from Huangpu River source water could only be achieved under an ozone dose as high as 4.0 mg/L in an ozone-biological activated carbon (O3- BAC) process, which would lead to the production of high concentrations of carcinogenic bromate due to the high bromide content. This study investigated the possibility of simultaneous control of bromate and the septic/swampy odor by adding H2O2 prior to the O3-BAC process for the treatment of Huangpu River water. H2O2 addition could reduce the bromate concentration effectively at an H2O2/O3 (g/g) ratio of 0.5 or higher. At the same time, the septic/swampy odor removal was enhanced by the addition of H2O2, although optimization of the H2O2/O3 ratio was required for each ozone dose. At an ozone dose of 2.0 mg/L, the odor was removed completely at an H2O2/O3 ratio of 0.5. The results indicated that H2O2 application at a suitable dose could enhance the removal of the septic/swampy odor while suppressing the formation of bromate during ozonation of Huangpu River source water.
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2014年第3期550-554,共5页 环境科学学报(英文版)
基金 supported by the National Natural Science Foundation of China(No.50938007) the Funds for Major Science and Technology Program for Water Pollution Control and Treatment(No.2012ZX07403-002-02) the Shanghai Committee of Science and Technology Project(No.11XD1420500)
关键词 ozonatlon H2O2 BrO3^- suppression septic/swampy odor flavor profile analysis ozonatlon H2O2 BrO3^- suppression septic/swampy odor flavor profile analysis
  • 相关文献

参考文献22

  • 1APHA, AWWA, WEF, 1995. Standard methods for the examination of water and wastewater. American Public Health Association, 19th ed. Washington, DC.
  • 2Bader, H., Hoigne, 1., 1981. Determination of ozone in water by the indigo method. Water Res. 15(4),449-456.
  • 3Bader, H., Sturzenegger, v., Hoigne, 1., 1988. Photometric method for the determination of low concentrations of hydrogen peroxide by the peroxidase catalyzed oxidation of N,N-diethyl-pphenylenediamine (DPD). Water Res. 22(9), 1109-1115.
  • 4Bruchet, A., Duguet, 1. P., Suffe, I. H., 2004. Role of oxidants and disinfectants on the removal, masking and generation of tastes and odours. Rev. Environ. Sci. BioTechnol. 3(1), 33-41.
  • 5Chu, w., Gao, N., Yin, D., Deng, Y., Templeton, M. R., 2012. Ozonebiological activated carbon integrated treatment for removal of precursors of halogenated nitrogenous disinfection by-products. Chemosphere 86(11),1087-1091.
  • 6Croue, 1. P., Koudjonou, B. K., Legube, B., 1996. Parameters affecting the formation of bromate ion during ozonation. Ozone: Sci. Eng. 18(1),1-18.
  • 7Daniel, P. A., Zafer, M. A., Meyerhofer, P. E, 1995. Bromate control: Water quality, engineering, and operational considerations. Water SuppI.13(1), 169-176.
  • 8Glaze, W. H., Schep, R., Chauncey, w., Ruth, E. C., Zarnoch, K. J., Aieta, E. M. et al., 1990. Evaluating oxidants for the removal of model taste and odor compounds from a municipal water supply. 1. Amer. Water Works Assoc. 82(5), 79-84.
  • 9Haag, W. R., Hoigne, 1., Bader, H., 1984. Improved ammonia oxidation by ozone in the presence of bromide ion during water treatment. Water Res. 18(9), 1125-1128.
  • 10Hofmann, R., Andrews, R. c., 2001. Ammoniacal bromamines: A review of their influence on bromate formation during ozonation. Water Res. 35(3), 599-604.