期刊文献+

响应面法优化催化超临界水氧化法处理制药废水的研究 被引量:2

Treatment of pharmaceutical wastewater by CSCWO optimized using response surface methodology
下载PDF
导出
摘要 采用超临界水氧化法处理制药废水,考察温度、压力、停留时间、过氧量等因素对废水COD去除效果的影响;采用响应面分析法对实验结果进行数据分析和参数优化。结果表明,在最佳操作点温度压力25 MPa,392.54℃,氧化剂过量1.254倍,停留时间52.58 s的条件下,COD去除率达到最高值(98.92%)。 Adopting the supercritical water oxidation to treatment of pharmaceutical wastewater.Effects of temperature,reaction pressure,resident time and peroxide amount,etc.on degradation efficiency of COD were investigated.The catalytic supercritical water oxidation (CSCWO) experimental results were analyzed and optimized using response surface methodology.The results demonstrated that the optimum pressure,temperature,excess oxygen and residence time were found to be 25 MPa,392.54 ℃,1.254 times and 52.58 s,respectively and the highest COD removal efficiency(98.92%) could be achieved.
出处 《应用化工》 CAS CSCD 2014年第3期408-411,共4页 Applied Chemical Industry
基金 国家自然科学基金项目(51078252)
关键词 催化超临界水氧化 响应面法 制药废水 中心组合设计方法 CSCWO RSM pharmaceutical wastewater central composition design
  • 相关文献

参考文献7

  • 1Yu Jian, Savage P E. Catalytic oxidation of phenol over MnO2 in supercritical water [ J ]. Ind Eng Chem Res, 1999,38 (10) :3795-3801.
  • 2杨玉敏,董秀芹,张敏华.苯酚在超临界水中的催化氧化反应[J].石油化工,2004,33(10):987-991. 被引量:8
  • 3Ding Z Y, Frisch M A, Li L, et al. Catalytic oxidation in supercritical water[J]. Ind Eng Chem Res, 1996 (35) : 3257.
  • 4Mason R L, Gunst R F, Hess J J. Statistical Design and Analysis of Experiments with Applications to Engineering and Science [ M I. The United States of America: John Wiley and Sons Publication,2003.
  • 5Arslan-Alaton I, Akin A, Olmez-Hanci T. An optimization and modeling approach for H202/UV-C oxidation of a commercial non-ionic textile surfactant using central com- posite design[ J]. Journal of Chemical Technology & Bio- technology,2010,85 (4) :493-501.
  • 6吴彦瑜,周少奇,覃芳慧,赖杨岚,彭华平.响应面法优化Fenton处理难降解反渗透垃圾浓缩渗滤液[J].环境工程学报,2010,4(11):2494-2498. 被引量:32
  • 7Zhang H, Choi H J. Multivariate approach to the Fenton process for the treatment of landfill leaehate [ J ]. Journal of Hazardous Materials ,2009,161 (2/3) : 1306-1312.

二级参考文献54

  • 1戴启洲,周明华,雷乐成.响应面法优化湿式氧化处理阳离子红X-GRL废水[J].浙江大学学报(工学版),2006,40(11):1889-1894. 被引量:13
  • 2傅剑锋,武秋立.响应面法分析Fenton氧化垃圾渗滤液的过程[J].化工进展,2006,25(12):1493-1495. 被引量:19
  • 3[1]Aki S N V K, Ding Zhongyi, Abraham M A. Catalytic Supercritical Water Oxidation: Stability of Cr2O3 Catalyst. AIChE J, 1996, 42(7):1 995~2 003
  • 4[2]Yang H H,Eckert C A. Homogeneous Catalysis in the Oxidation of p -Chlorophenol in Supercritical Water. Ind Eng Chem Res, 1988,27(11) :2 009~2 014
  • 5[3]Ahmet M G,Anthony A C,Keith D B. The Catalytic Role of Transition Metal Salts on Supercritical Water Oxidation of Phenol and Chlorophenols in a Titanium Reactor. React Kinet Catal Lett ,2003,78(1) :175~182
  • 6[4]Satterfield. Heterogeneous Catalysis in Industrial Practise. 2nd ed.New York: McGraw Hill Inc, 1991
  • 7[5]Ding Zhongyi, Frisch M A, Li Lixiong, et al. Catalytic Oxidation in Supercritical Water. Ind Eng Chem Res, 1996,35: 3 257~ 3 279
  • 8[6]Krajnc M,Levec J. Catalytic Oxidation of Toxic Organics in Supercritical Water. Appl Catal, B, 1994,3: L101 ~ L107
  • 9[7]Ding Zhongyi,Aki S N V K, Abraham M A. Catalytic Supercritical Water Oxidation: Phenol Conversion and Product Selectivity. Environ Sci Technol, 1995,29 ( 11 ): 2 748 ~ 2 753
  • 10[8]Yu Jianli, Philip E S. Catalytic Oxidation of Phenol over MnO2 in Supercritical Water. Ind Eng Chem Res, 1999,38:3 793~3 801