摘要 An increasing number of annealing furnaces have recently been using cheaper and cleaner natural gas (NG) instead of liquefied petroleum gas (LPG) as fuel gas.However,the fuel gas of the furnaces often needs to be changed when NG supply is not adequate or when LPG becomes cheaper.Usually,changing the fuel gas involves changing various equipment as well as control parameters for instruments and the control system and hence is time consuming.Therefore,it is important to develop a quick process for changing fuel gas.This study discusses the techniques for quickly changing fuel gas in an annealing furnace.These techniques deal with the design of the pipe,valve and burner,the selection of the flow meter and the flow control valve,the switch of the software and parameters for the control system,as well as the operation,commissioning and hot test of the furnace when the fuel gas is changed.Using these techniques,it is possible to change fuel gas in 6 h. An increasing number of annealing furnaces have recently been using cheaper and cleaner natural gas (NG) instead of liquefied petroleum gas (LPG) as fuel gas.However,the fuel gas of the furnaces often needs to be changed when NG supply is not adequate or when LPG becomes cheaper.Usually,changing the fuel gas involves changing various equipment as well as control parameters for instruments and the control system and hence is time consuming.Therefore,it is important to develop a quick process for changing fuel gas.This study discusses the techniques for quickly changing fuel gas in an annealing furnace.These techniques deal with the design of the pipe,valve and burner,the selection of the flow meter and the flow control valve,the switch of the software and parameters for the control system,as well as the operation,commissioning and hot test of the furnace when the fuel gas is changed.Using these techniques,it is possible to change fuel gas in 6 h.
出处 《Baosteel Technical Research》 CAS 2014年第1期52-57,共6页 宝钢技术研究(英文版)
关键词 APL NG LPG double limit ratio control flow meter APL NG LPG double limit ratio control flow meter
  • 相关文献

参考文献5

  • 1Lai Yuankai. Standard calorific value selection of naturegas[ Jl. World Oil & Gas ,2006( 3 ) :25 - 28.
  • 2OMEDA Engineering, Inc. Liquid flowmeter flow reference section ~ EB/OL 1. [ 2014-2-81. bttp ://www. omega, com/techref/flowcontrol, html.
  • 3Liu Xinrong. Flowmeter (2rid ed. ) { M 1- Beijing ~ China Water Power Press, 1989 -50 - 53.
  • 4Tongji Universality, Chongqing Civil Engineer and Architecture College, Harbin Civil Engineer and Architecture College, et al. Gas combustion and application ( 2nd Edition ) EM]. Beijing: China Architecture & Building Press, 1988.
  • 5Jiang Renjie, Piao Rilong, Sun Xiaocbun, et al. t~XL DCS application manual EM], Beijing: ChemistryIndustry Press, 1997.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部