摘要 目的:探讨微柱凝胶卡式法对新生儿溶血病(HDN)的诊断价值。方法:选取2012年7月-2013年7月本院儿科收治的疑似ABO母婴血型不合新生儿溶血病的278例新生儿血标本,分别用微柱凝胶卡式法和传统试管法进行直接抗人球蛋白试验、间接抗人球蛋白试验和放散试验,并对检测结果进行比较。结果:278例中临床确诊263例。微柱凝胶卡式法的直接抗人球蛋白试验阳性率76.4%明显高于试管法的59.3%,抗体游离试验阳性率90.5%明显高于试管法的66.2%,抗体放散试验阳性率99.2%明显高于试管法的79.1%,差异均有统计学意义(P<0.001)。结论:微柱凝胶卡式法对于辅助诊断HDN优于传统试管法,操作简单,耗时短,结果易观察,值得在临床上推广。 Objective:To investigate value of micro column gel card method and test tube method in diagnosis ABO hemolytic disease of newborn.Method:278 blood samples of newborn suspected case of hemolytic disease of the newborn (HDN)with maternal fetal ABO blood incompatibility from July 2012 to July 2013 in department of pediatrics in our hospital were selected.The HDN three tests of direct Coombs test,serum free antibody,elution test were checked with the two methods of micro column gel card and test tube respectively.The detection results of two methods were compared.Result:In 278 cases,263 cases of clinically were confirmed.The positive rates of direct Coombs test in micro column gel card method was 76.4%,it was significantly higher than 59.3%in test tube method,the serum free antibody was 90.5%,it was significantly higher than 66.2%in test tube method,and elution test was 99.2%,it was significantly higher than 79.1%in test tube method,the differences were statistically significant(P〈0.001).Conclusion:Micro column gel card method is simpler operation,rapid,easier to observe the results than the methods of test tube and is worth in clinical promotion.
作者 钟水权
出处 《中国医学创新》 CAS 2014年第9期34-36,共3页 Medical Innovation of China
关键词 微柱凝胶卡式法 试管法 ABO 新生儿溶血病 Micro column gel card Test tube method ABO Hemolytic disease of the fetus and the newborn
  • 相关文献

参考文献11

二级参考文献71

共引文献64

同被引文献59

引证文献8

二级引证文献34

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部