摘要 将采用螺栓和栓筋两种连接方式的装配整体式钢板箍短柱的抗震试验结果与普通钢筋混凝土短柱和高强螺旋箍现浇钢筋混凝土短柱的抗震性能进行了对比研究,结果表明,螺栓和栓筋这两种连接方式的装配整体式短柱的抗震性能均优于普通钢筋混凝土短柱而与高强螺旋箍现浇钢筋混凝土短柱的抗震性能相当,这两种节点构造连接可靠、安全,可以用于实际工程中。对这两种连接方式的优异性进行了对比研究,表明低剪跨比的螺栓连接短柱具有更优的抗震性能。 The seismic performance of two types' assembled monolithic short column encased by steel plate hoop and jointed by bolt or bolt bar was separately contrasted to that of ordinary reinforced concrete short columns and rein- forced concrete short columns cast in situ and equipped with high strength spiral hoop. The results show that the seismic performance of two types' assembled monolithic short column is superior to that of ordinary reinforced con- crete and equivalent to that of reinforced concrete short column with high strength spiral hoop ; The two types of node structure connection are safe enough and can be used to practical engineering. In addition, the two types of con- necting methods were compared each other and the results suggest that the short column jointed by bolt with low shear span ratio has a better seismic performance .
出处 《世界地震工程》 CSCD 北大核心 2014年第1期29-33,共5页 World Earthquake Engineering
基金 河北省地方科技项目(2011188):新型抗震装配整体式混合结构体系试验研究
关键词 装配整体式 短柱 钢板箍 螺栓 栓筋 抗震性能 assembled monolithic short column steel plate hoop bolt bolt bar seismic performance
  • 相关文献

参考文献1

二级参考文献3

  • 1辽亍省住房和城乡建设厅.装配整体式混凝土结伺技术规程(暂行)[s].2011-02-01.
  • 2L·莫克,E·栗凯,著,钢筋混凝土装配式建筑[M].傅信祁,徐鼎新,等译.北京:中国建筑工业出版社,1985.
  • 3陆湘桥.日本工业化住宅一瞥[J].建筑施工,2001,23(4):207-209. 被引量:4

共引文献31

同被引文献9

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部