期刊文献+

Straumann种植体早期负荷与延迟负荷的临床稳定性效果比较 被引量:2

原文传递
导出
摘要 目的探讨Straumann种植体在种植过程中早期负荷与延迟负荷的临床稳定性效果。方法将64例牙列缺损患者随机分为早期负荷组与延迟负荷组,每组32例,比较两组患者实施不同临床处理措施后的临床稳定性效果(ISQ值测量)。结果两组患者分别在实施手术后的当日,术后1,4、6、8、12周等比较,差异无统计学意义(P〉0.05)。结论在临床使用Straumann种植体的实际过程中,采用早期负荷与延迟负荷的临床稳定性效果差异无统计学意义(P〉0.05),采用早期负荷也能取得显著的稳定性效果,是临床治疗手段上的可靠选择。
出处 《中国实用医刊》 2014年第7期126-126,F0003,共2页 Chinese Journal of Practical Medicine
  • 相关文献

参考文献10

二级参考文献95

共引文献73

同被引文献19

  • 1叶平,涂慧娟,吴润发,林萍,白彭,戴勇中.即刻与延期种植修复单个上颌中切牙龈乳头——外形美观的比较性研究[J].中国口腔种植学杂志,2009,14(2):53-54. 被引量:8
  • 2林野.当代口腔种植学的进展及其临床意义[J].口腔颌面外科杂志,2006,16(4):285-290. 被引量:69
  • 3Deporter DA, Watson PA, Pilliar RM, et al. A histological assess- ment of the initial healing response adjacent to porous surface [ J ]. J Dent Res, 1986,65 ( 8 ) : 1064-1070.
  • 4Tinti C, Benfenati SP. The bump mattress suture: a new suture technique combined with a surgical procedure to obtain between implants in buccal area [ J ]. Int J Periodont Rest Dent, 2002,22 ( 1 ) :63-69.
  • 5Canullo L, Iannello G, Pefiaroeha M, et al. Impact of implant di- ameter on bone level ehanges around platform switehed implants: Prelimi-nary results of 18 months follow-up a prospective random- ized mateh-paired controlled trialed controlled trial[ J]. Clin Oral Implants ires,2012,23 ( 10 ) : 1142-1146. DOI : 10.1111/j. 1600- 0501. 2011. 02297. x.
  • 6Lazzara ILl, Porter SS. Platform switching: a new eoneept in im- plant dentistry for eontrolling postrestorative erestal hone levels [ J ]. Int J Periodonties Restorative Dent, 2006,26 ( 1 ) : 9-17.
  • 7Gaetti-Jardim EC, Santiago-Junior JF, Goiato MC, et al. Dental implants in patients with osteoporosis : a clinical reality [ J ]. J Crauiofac Surg, 2001,22 (3) : 1111-1113. DOI: 10. 1097/SCS. 0b013e3182108ee9.
  • 8Hsu JT, Fuh L J, Tu MG, et al. The effects of cortical bone thick- ness and trabeeular bone strength on noninvasive measures of the implant primary stability using synthetic bone models [ J 1. Clinical Implant Dentistry and Related Research, 2011, ( 2 ) : 135-138. DOI : 10.1111/j. 1708-8208. 2011. 00349. x.
  • 9Pagliani L, Andersson P, Lanza M, et al. A eollagenated porcine bone substitute for augmentation at neoss implant sites : a prospec- tive 1-year muhieenter case series study with histology[ J ]. Clini- cal Implant Dentistry and Related Research, 2010, ( 5 ) : 746 -758. DOI:10.1111/j. 1708-8208. 2010.00314. x.
  • 10Tabassum A, Meijer GJ, Wolke JG, et al. Influence of surgical technique and surface roughness on the primary stability of an im- plant in artificial bone with different cortical thiekness:a laborato- ry study [ J ]. Clinical Oral Implants Research, 2010, ( 2 ) : 568- 571. DOI : 10.1111/j. 1600-0501. 2009. 01823. x.

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部