摘要 研制了一台连续回热型吸附式空调 /热泵 ,对吸附床设计进行了改进 ,并在样机上采取一系列控制措施 ,使工况稳定。通过改变热源温度、蒸发温度、循环周期等参数 ,获取多组实验数据 ,该样机在 1 0 0℃热源驱动下 SCP达到 1 50 W/ kg,COP达 0 . A continuous heat regenerative adsorption heat pump prototype using actived carbon methanol pair has been developed.In this system a SCP of 150w/kg (Specific Cooling Power)and a COP of 0.21 (Coefficient Of Performance)were obtained.In other to increase COP and keeping high SCP,two novel adsorbers are designed to replace the formar adsorbers.Some control methods are used in the system to make working condition stable.By means of many experiments,SCP and COP versus evaporating temperature,cycle time and heat source temperature are obtained.A group of optimum operative parameters are chosen.The developed new system has a COP of 0.4 and a SCP of 150W/kg
出处 《太阳能学报》 EI CAS CSCD 北大核心 2000年第2期198-203,共6页 Acta Energiae Solaris Sinica
关键词 吸附式空调 性能试验 制冷 连续回热型 adsorption heat pump,performance test,refrigeration
  • 相关文献

参考文献3

二级参考文献5

  • 1Wang R Z,ASME J Solar Energy Engineering,1999年
  • 2Wang R Z,Appl Thermal Engineering,1998年,18卷,1期,13页
  • 3Teng Y,Appl Thermal Engineering,1997年,17卷,4期,327页
  • 4Wang R Z,Proc Int Absorption Heat Pump Conf,1996年,1卷,587页
  • 5王如竹,吴静怡,滕毅,许煜雄,施雯,杨利民,汪前彬.固体吸附式制冷的关键技术研究[J].太阳能学报,1998,19(1):20-29. 被引量:29