摘要
介绍了6万t/a氯工程离子膜电解装置情况,给出离子膜电解装置第1—7个月运行数据,指出装置运行过程中存在的问题,并提出优化装置运行的措施。
A 60 kt/a ion-exchange membrane electrolysis facility made by Chlorine Engineering Co. was introduced. The data of its running during the period from the first month to the seventh month were presented. The problems occurred during the running were analyzed and optimization measures were proposed.
出处
《氯碱工业》
CAS
2014年第3期16-18,共3页
Chlor-Alkali Industry
关键词
离子膜电解装置
运行分析
优化措施
ion-exchange membrane electrolysis facility
analysis of running
optimization measure