摘要 从供电实际出发,以Atmega单片机为设计核心设计企业自备电厂综合监控系统,主要从电源供电和无功分配调节两个方面入手。电源供电直接为系统运行提供可靠保障;无功调节部分提高系统承受谐波的能力,使无功分配更加合理。 Designs a comprehensive monitor system based on single chip microcomputer Atmega series, which is particularly adapted to enterprises-owned power plant. The system includes two important parts: power resources which ensures qualified operation condition and regulation of reactive power distribution. It can improve the system's ability of undertaking harmonic and rationally distributes the reactive power.
出处 《现代计算机》 2014年第3期56-61,共6页 Modern Computer
关键词 单片机 电源 无功调节 Single Chip Microcomputer Power Resources Regulation of Reactive Power
  • 相关文献

参考文献15

二级参考文献18

  • 1杨冠城.电力系统自动装置原理[M].中国电力出版社,1985..
  • 2张俊谟.《单片机中级教程》[M].北京航空航天大学出版社,2002,8..
  • 3RFC 1661 .The point to point protocol(PPP)[S].
  • 4RFC 1662.PPP in HDLC-like framing [S].
  • 5张伯明.高电力网络分析(AdvancedPowerSystemNetworkAnalysis),ChenShousun),陈寿孙(ZhangBoming,Tsinghua University Press)[M].北京:清华大学出版社(Beijing,1996..
  • 6C W Taylaor.Concept of Undervoltage Load Shedding for Voltage Stability[J].IEEE Trans on PWRD,.1992,7(2):480-8.
  • 7王伟胜 译.电力系统电压稳定[M].北京:中国电力出版社,2002..
  • 8A M Abed.WSCC Voltage Stability Criteria,Undervoltage Load Shedding Strategy,And Reactive Power Reserve Monitoring[M].IEEE,1999:191-197.
  • 9Voltage Stability Working Group.Summery of "System Protection and Voltage Stability"[J].IEEE Trans on PWDS.1995,10(2):631-638.
  • 10UVLSTF Technical Studies Subcommittee Western System Coordinating Council.Undervoltage Load shedding Guidelines.1999.

共引文献105

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部