针对我厂 5 0 0 0 t/a硫磺回收装置开工运行中存在的问题及尾气排放的现状进行了分析 ,指出了尾气 SO2 排放超标的影响因素和主要原因 。
The operation trouble and present situation of the tail gas discharge were analyzed, after 5000 t/a sulfur recovery plant was put into operation in SINOPEC Cangzhou Refinery more a half year. SO 2 content in the tail gas has not reached discharge standard, its effect factors and main reason have been found out, and its countermeasure and treatment plan have been provided.
出处
《石油化工环境保护》
2000年第4期32-34,共3页
Environment Protection in Petrochemical Industry
关键词
硫磺装置运行
尾气排放
现状
治理对策
Operation of sulfur recovery plant
Discharge of tail gas
Presentsituation
Treatment countermeasure