摘要 本文通过分析深圳地区杆塔特点、气象特点、登塔作业特点,根据不同塔形,综合国内外各种防坠落导轨的优缺点,结合笼式爬梯、休息平台等作用特点,研究全程便捷的防护安全措施,探讨研究出一套适用于深圳地区杆塔的防坠落方案,该方案对深圳电网的防坠落装置安装具有指导意义。 It is that this paper focuses attention on analyzing the features o)f towers in Shenzhen area, the characteristics of climate and the features of the job of climbing towers.By reaching the different shape of the towers,multiplying the merits and faults of various anti-falling guide,combining with the characteristics of cage ladder and rest platform,and studying the safety and convenient prevention measures in the whole work,a scheme which is suit for Shenzhen area to preventing falling from the tower is researched.This scheme is a guide of the anti-falling device to the Shenzhen power grid.