摘要
列举了GB7588—2003对电梯开门情况下的平层和再平层运行的条件要求;指出电梯开门情况下的平层和再平层检查装置是电气安全装置;探讨了满足相关机械安全标准及电梯产品标准要求的开门情况下的平层和再平层检查装置的设计,并给出了设计实例。
The condition requirements of elevator leveling and re-leveling with the door open are listed according to GB 7588-2003. The detection device of elevator leveling and re-leveling with the door open is identified as an electric safety device. The design of the detcetion device according to the relevant safety codes for elevator and machinery is discussed, and a design example is given in this paper.
出处
《中国电梯》
2014年第5期5-9,共5页
China Elevator
关键词
电梯
开门
电气安全回路
电气安全装置
安全电路
平层和再平层
检查装置
elevator
opening door
electric safety chain
electric safety device
safety circuit,leveling and re-leveling
detection device