摘要
根据垃圾填埋场渗滤液回灌处理的特点 ,提出了调蓄水池容量的计算方法。
According to the process of the landfill leachate\|recirculation,the design method for sizing the storage pond of leachate was proposed by analyzing the production of collected leachate.Some problems were discussed for reliable design.
出处
《环境工程》
CAS
CSCD
北大核心
2000年第6期53-56,共4页
Environmental Engineering
关键词
回灌法
渗滤液
调蓄池
降雨渗透
渗漏
leachate-recirculation
leachate
storage pond
seepage of precipitation and leak