叙述某台PG9171E型燃气轮机在改用DLN-1.0燃烧系统后出现的问题,如一区喷嘴环形锁片脱落、一区重点火等,并提出相应的解决措施,优化技改方案,提高配备DLN-1.0燃烧系统燃气轮机运行的可靠性。
Problems after the DLN-1.0 combustion system conversion in the PG9171E gas turbine were described, such as the primaryfuel nozzle ring migration, the primary zone re-ignition.And the corresponding solution measures was proposed , which can improvethe reliability of the gas turbine operation after the DLN-1.0 conversion.