摘要
针对拾屯煤矿自然发火的现状,首先采取启封密闭、可疑点分析,寻找漏风点,然后基于束管监测数据分析了封闭前后火区的燃烧状况,并采取构筑均压气室、布置均压管路,建立均压系统,结合《煤矿安全规程》,使得CO超限得到有效治理。
According to the present situation of spontaneous combustion of Shitun coal mine,first unsealed airtight suspects analysis,looking for air leakage points,and then based on the tube of combustion condition monitoring data before and after the analysis of the fire area,and to construct all compressed air room,decorate equalizing line,establish equalizing system,combined with the “coal mine safety regulations”,makes CO transfinite governance effectively.
出处
《山东煤炭科技》
2014年第1期65-66,68,共3页
Shandong Coal Science and Technology
关键词
预防
一氧化碳
综合效果
prevention Carbon monoxide
comprehensive effect