为解决多点式风量测量装置在安装使用过程中存在的问题,保证磨煤机一次风量测量的稳定性和准确性,利用精准定位测量装置安装位置、改善测量装置的支撑方式和优化逻辑控制参数,对多点式风量测量装置的应用机理进行全面的分析研究,最终使磨煤机入口一次风量测量稳定、精确度高、自动投入率达100%,达到了预期的效果.
To solve the multi-point air flow measuring device in the installation process problems, ensure the stability and accuracy of measurement of an amount of wind mill. By precise positioning of the measuring device installation location, supporting ways to improve and optimize the measurement device logic control parameters, The application of the mechanism of multi-point air flow measuring device to conduct a comprehensive analysis, and finally to the mill entrance of a wind measurement stability, high accuracy, automatic input rate of 100%, which achieves the desired effect.