摘要 地埋管地源热泵以浅层地热能资源作为供冷冷源和供热热源,是建筑节能领域内最高效的技术之一。近年来地埋管地源热泵技术在河北省发展尤为迅速,但也出现了诸多问题。地埋管地源热泵的适宜性研究得到越来越多人的重视。本文通过对河北地区(主要是京津以南河北地区)地质构造以及水文条件的勘察了解,运用河北省地源热泵检测中心与河北省科学院能源研究所联合开发的的岩土热响应测试仪,对该地区做了大量的热响应试验测试,积累了丰富的数据资料。利用二维线热源传热模型采用"恒功率"和"恒温法"对测试项目的岩土导热系数和单位埋深的换热量做了相应的求解计算,结合地质构造从经济性和换热效率两方面综合考虑对地埋管地源热泵在河北地区的适宜性进行了一定的划分,得到并不是所有的地方都适合做地埋管地源热泵项目。研究旨在为河北地区地热能的开发与利用起到一定的推动作用,为河北省地埋管地源热泵热泵的设计、施工等方面提供一定的参考。 Ground source heat pump is one of the most efficient technologies in the field of building energy saving,which uses the shallow geothermal energy as heat and cold source. In recent years,ground source heat pump technology develops especially rapidly in Hebei prov- ince,there also had many problems. The study on suitability of ground source heat pump is gaining attention from more and more people. In this paper, the geological survey and hydro- logical conditions of Hebei region (mainly south of Beijing and Tianjin) was explored,and the thermal response test equipment which was jointly developed by Hebei test center of ground source heat pump and Hebei Province Academy of Sciences was used to do a wealth of thermal response test ,and a large quantity of sources and data were calculated. The method of "con- stant power" and "isothermal" and Line heat transfer model were used ,and the thermal con- ductivity of soil and the heat exchange of unit depth were calculated, combined with geological tectonic situation, both the economy and efficiency of heat transfer were considered, and the suitability partition of Ground source heat pump used in Hebei was analyzed, the results show that ground source heat pump was not suitable for all places. The purpose of this paper is to promote the development and utilization of geothermal energy in Hebei province and provides a reference for the design and construction of ground source heat pump.
出处 《河北省科学院学报》 CAS 2013年第4期50-58,共9页 Journal of The Hebei Academy of Sciences
关键词 浅层地能 地源热泵 热响应试验 适宜性 Shallow geothermal energy Ground source heat pump Thermal responsetest Suitability
  • 相关文献

参考文献10

  • 1庄迎春,王哲.地源热泵技术在建筑节能中的应用[J].建筑技术,2004,35(12):909-910. 被引量:11
  • 2刘自强,刘伟,王建辉,等.河北省浅层地能调查[M].石家庄:河北科学技术出版社.2009.
  • 3吕灿仁,热泵及其在我国应用的前途[J].动力机械,1957,(2).
  • 4KAVANAUGH SP. Field tests for ground thermal properties-methods and impact on ground source heat pump design E J] ASHRAE Transactions, 2000,106 ( 1 ) : 851 -- 855.
  • 5张金堂,郎洪钢,朱学思.河北省水资源开发利用问题与对策[J].河北水利,2009(8):7-8. 被引量:2
  • 6T KATSURA,K NAGANO,S TAKEDA,et al. Develop-ment of a design and performance prediction tool for the ground source heat pump system [J]. Apply Thermal Engineering,2006,26:1578--1592.
  • 7P ROTH,A GEORGIEV, A BUSSO,et al. First in sit determination of ground and borehole thermal properties in I.atin America [J]. Renewable Energy,2004,29(12) : 1947-- 1963.
  • 8乔卫来,陈九法,薛琴,郑红期.地埋管换热器热响应测试与模拟研究[J].建筑热能通风空调,2010,29(1):1-4. 被引量:12
  • 9IGSHPA (International Ground Source Heat Pump Association). Closed-Loop/ Geothermal Heat Pump Systems- Design and Installation Standards (2007 Edition) [M]. USA : Oklahoma State University, 2007.
  • 10ASHRAE. 2007 ASHRAE handbook on HVAC applications[M]. Atlanta: American Society of Heating,Refrigerating and Air-Conditioning Engineers, Inc. , 2007.

二级参考文献12

  • 1余延顺,马最良.土壤耦合热泵系统地下埋管换热器传热模型的研究[J].暖通空调,2005,35(1):26-31. 被引量:21
  • 2高杉 真司·池内.中国长春市·极寒冷地ヘの地中热利用ヒトポンブ技术の适用·普及调查·技术情报[J].地热,2001,38(6):166-166.
  • 3Sarah Signorelli,Simone Bassetti.Numerical evaluation of thermal response tests[J].Geothermics,2007,36:141-146.
  • 4Yuehong Bi,Lingen Chen,Chih Wu.Ground heat exchanger temperature distribution analysis and experimental verification[J].Apply Thermal Engineering,2002,22:183-189.
  • 5Hikmet Esen,Mustafa Inalli.In-situ thermal response test for ground source heat pump system in Elaz?g,Turkey[J].Energy and Buildings,2009,41:395-401.
  • 6Katsunori Nagano,Takao Katsura.Development of a design and performance prediction tool for the ground source heat pump system[J].Apply Thermal Engineering,2006,26:1578-1592.
  • 7P Roth,A Georgiev,A Busso.First in situ determination of ground and borehole thermal properties in Latin America[J].Renewable Energy,2004,29:1947-1963.
  • 8[1]庄迎春.直埋式地源热泵系统技术研究与应用[D],长春:吉林大学,2002
  • 9陆志,连之伟,刘蔚巍,兰丽.地源热泵竖直埋管数值线源综合模型[J].上海交通大学学报,2008,42(3):409-414. 被引量:9
  • 10储国成,余跃进,蔡宗良.地源热泵不同运行模式埋管进出口温度模拟及实验验证[J].南京师范大学学报(工程技术版),2008,8(3):30-34. 被引量:2

共引文献22

同被引文献33

引证文献3

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部