摘要 采用电感耦合等离子体原子发射光谱-标准加入法(ICP-AES-标准加入法)探讨铝合金中痕量钠的测定.以盐酸、过氧化氢溶解试料,优化全谱型ICP-AES分析条件,标准加入法测定铝合金中痕量钠,检出限为0.028 μg/mL(588.995 nm).用该方法测定铝合金中0.00014%~0.00073%钠含量,加标回收率在92%~110%之间,连续测定5个结果的相对标准偏差小于0.25%. A method was studied for the determination of trace sodium content in aluminum alloy by ICP - AES. By using hydrochloric acid and hydrogen peroxide 30% to dissolve samples, trace sodium content in the aluminum alloy were determined according to the optimum condition of ICP - AES. the detection limit were 0. 028 μg/mL(588. 995nm). The results of trace sodium content were between 0. 00014% - 0. 00073%. The relative standard deviations of five samples was less than 0. 25%.
出处 《四川冶金》 CAS 2013年第6期53-56,共4页 Sichuan Metallurgy
关键词 ICP-AES 标准加入法 铝合金 痕量钠 ICP - AES aluminum alloy trace sodium
  • 相关文献

参考文献4

  • 1GB/T20975.25-2008.铝及铝合金化学分析方法[s].第25部分:电感耦合等离子体原子发射光谱法.
  • 2GB/T13748.17-2005.镁及镁合金化学分析方法[s].钾含量和钠含量的测定.
  • 3火焰原子吸收光谱法.辛仁轩.等离子体发射光谱分析[M].第1版.北京:化学工业出版社,2005.
  • 4李芬,李启华,周西林,马英,樊朝英.电感耦合等离子体原子发射光谱法测定防锈铝合金中痕量钠[J].理化检验(化学分册),2012,48(4):465-466. 被引量:5

二级参考文献3

  • 1张素华,李庆华,郭至修.离子选择电极法测定高硅防锈铝合金中的钠[J].冶金分析,1984,4(4):6464.
  • 2GB/T13748.172005镁及镁合金化学分析方法钾含量和钠含量的测定火焰原子吸收光谱法[s].
  • 3王滨滨.高镁铝合金的钠脆性[J].黑龙江冶金,2009,29(3):12-14. 被引量:15