摘要
本文通过锅炉设计技术措施研究,以及改造后锅炉热力计算和烟风动力计算从技术上完善了将65 t/h煤粉锅炉改造成65 t/h抛煤机倒转链条炉排锅炉的设计。
In this presentation, the working scheme retrofitting a 65 t/h pulverized-coal fired boiler into a travelling-grate spreader stoker boiler was depicted. On the basis of this, the retrofitting heat calculations, the calculations of air and flue gas pressure drops, and the strength calculations of pressure parts were carried out. The technical measures for the retrofitting were discussed in detail.
出处
《能源研究与信息》
2000年第1期18-23,共6页
Energy Research and Information