期刊文献+

热敏感性对直流锅炉水冷壁安全运行的影响 被引量:3

The Effect of Heat Sensitivity on the Safe Operation of Once through Boiler Water Walls
下载PDF
导出
摘要 根据汽液两相流动阻力的计算式 ,推导出了流量敏感系数、出口焓值敏感系数的表达式。对直流锅炉内螺纹管、螺旋管圈水冷壁的热敏感系数进行了定量计算 ,分析了各种因素对热敏感性的影响 ,并对两种水冷壁管屏在热负荷不均时的温度偏差、焓值偏差进行了讨论 。 On the basis of a calculation formula for two phase flow resistance derived is an expression of the sensitivity factor for the flow rate and outlet enthalpy. A quantitative computation is conducted of the heat sensitivity factor for the threaded tubes and spiral tube coils of the water walls of an once through boiler. The effect on the heat sensitivity of various factors is analyzed. In addition, discussed are the temperature and enthalpy deviations of two types of water wall panel in the case of non uniform heat loads. The present paper can offer some helpful hints for achieving the safe operation of once through boilers.
机构地区 西安交通大学
出处 《热能动力工程》 CAS CSCD 北大核心 2000年第5期473-476,共4页 Journal of Engineering for Thermal Energy and Power
关键词 直流锅炉 安全运行 热敏感性 水冷壁 once through boiler, sensitivity analysis, boiler water wall