摘要
根据CSM01 010 103-2006要求,对石墨炉原子吸收测定大米粉中镉含量的结果进行不确定度评定。结果表明,大米粉中镉含量为(162±6)μg/kg。测量重复性、标准溶液配制和标准曲线是不确定度的主要来源,其中测量重复性产生的不确定度影响最大。
The uncertainty evaluation for the determination of cadmium content with graphite furnace atomic absorption spectrometry in rice flour was measured according to CSM01010103-2006. The result showed that content of cadmium in rice flour was (162 ± 6) μg/kg, the repeated measurements, the preparation of standard solutions and the standard curve were the main sources of uncertainty and the repeated measurements had the most effect on the uncertainty.
出处
《上海医药》
CAS
2014年第6期47-49,共3页
Shanghai Medical & Pharmaceutical Journal
关键词
石墨炉原子吸收
镉
大米粉
不确定度
graphite fumace atomic absorption
cadminm
uncertainty