介绍了电网 (配网 )运行中 ,运行电压、功率因数对运行经济性的影响 ,论证了在运行电压、功率因数允许范围内 ,要求两者尽量接近上限水平 ,从而获得更佳降损的节能效益。
This article analyses and explores the influence of the power system voltage and power factor fluctuation on the economic benefit, demonstrating that the voltage and power factor approaching the upper limit of allowable deviation will have a better economic benefit.
出处
《能源工程》
2000年第6期19-21,共3页
Energy Engineering