通过分析低温环境下风冷热泵型空调机组制热能力降低的主要原因 ,提出了在低温环境下提高风冷热泵型空调机组蒸发温度的方法及措施 ,并通过计算来验证其可行性。
This paper studies the main causes for capacity reduction of the heat pump air conditioner while working at low temperature environment,proposes methods to raise the evaporation temperature of the heat pump air conditioner and to prove the feasibility by calculation.
出处
《节能技术》
CAS
2001年第1期6-7,共2页
Energy Conservation Technology
关键词
热泵
低温环境
空调机组
风冷
heat pump
low temperature environment
heating capacity
evaporation temperature