期刊文献+

600MW机组电站凝汽器水侧流动的分析 被引量:2

Numerical simulation of water side in condenser of 600MW power station
下载PDF
导出
摘要 选取某电厂600MW机组凝汽器水侧流场进行数值模拟,研究流体的流动状况。模拟结果显示,凝汽器进口水室内存在涡旋,涡旋的存在增加了流体的流动阻力,使流动恶化,流量分布的不均匀,严重影响了设备的换热性能。在使用过程中,应采取措施减小涡旋,计算结果可以为凝汽器设计和改进提供参考。 The condenser water flow field of the 600MW power station is simulated,to study fluid flow conditions. Simulation results show that the before of the condenser water,the vortices increase the flow resistance of the fluid,aggravate flow conditions,affecting the operation of the equipment's safety and economy. Therefore,it is necessary to take suitable measures to alleviate the influence of flow deflection on the condenser. The computation results are helpful to reasonable design of power plant condensers.
作者 林轶 安珂
出处 《节能》 2014年第3期32-34,4,共3页 Energy Conservation
关键词 凝汽器 水室 数值模拟 涡旋 condenser water chamber numerical simulation vortices
  • 相关文献

参考文献4

二级参考文献12

  • 1同济大学数学教研室.高等教学[M].北京:高等教育出版社,1987..
  • 2Zhao C Y,Int Commu Heat Mass Transfer,1997年,24卷,5期,587页
  • 3Liu J,Computers Fluids,1996年,25卷,8期,719页
  • 4李沛文,计算传热学研究与应用进展,1994年,119页
  • 5Zhang H L,J Therm Sci,1992年,1卷,4期,249页
  • 6Lo S H,Int J Numer Methods Fluids,1989年,28期,2695页
  • 7陶文铨,数值传热学,1988年,508页
  • 8同济大学数学教研室,高等数学,1987年
  • 9李竟生,陈崇希译.贝尔多孔介质流体动力学[M].北京:中国建筑工业出版社,1983:505~518.
  • 10Fluent Inc.FLUENT 6.0 User's Guide[Z].December 2001:6-119~6-122,6-130~6-131,6-17.

共引文献28

同被引文献12

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部