期刊文献+

利用SPMD采样技术监测丹江口水库中POPs

Using Semipermeable Membrane Devices (SPMD) to Determine POPs in Danjiangkou Reservoir
下载PDF
导出
摘要 利用半透膜被动采样技术(SPMD)对丹江口水库中多环芳烃(PAHs)和有机氯农药(OCPs)等物质进行了采集测定。结果表明,丹江口水库中这些污染物的浓度低于其他地方表面水域的测定结果,水质情况令人满意。但是,最近15年,其水体中多环芳烃的浓度不断上升,且在水库中的一些区域检测出有六氯苯(HCB)的存在。研究表明,SPMD结合其他分析方法的技术手段为检测环境水样中持久性有机污染物提供了新的思路和发展前景。 Bioavailable concentrations of polycyclic aromatic hydrocarbons (PAils) and organochlorine pesticides (OCPs) were investigated in the water column of Danjiangkou Reservoir from March to May 2009 using semipermeable membrane devices (SPMD). Results showed that the levels of these contaminants in the Reservoir were low compared with other surface waters and are not Manning. But in regards to the concentrations of PAHs increasing in the latest 15 years and HCB contaminants did exist in some area in the Reservoir. The study indicates that SPMD sampling in combination with chemical analyses would provide an effective tool for the identification of environmentally relevant water borne trace hydrophobic pollutants in drinking water reservoir.
出处 《环境科学与技术》 CAS CSCD 北大核心 2014年第4期113-117,共5页 Environmental Science & Technology
基金 湖北省重点饮用水源地微量有机污染物监测与控制名单研究(湖北省环保厅环保科研项目 2007)
关键词 SPMD 持久性有机污染物 丹江口水库 semipermeable membrane devices (SPMD) POPs Danjiangkou Reservoir
  • 相关文献

参考文献17

  • 1Kees Booij, Foppe Smedes, Evaline M van Weerlee. Spiking of performance reference compounds in low density polyethy~ene and silicone passive water samplers[J]. Chemosphere, 2002(46): 1157-1161.
  • 2Prest HF, Richardson BJ, Jacobson LA, et al. Monitoring organochlorines with semipermeable membrane devices ( SPMDs ) and mussels (Mytilus edulis) in Corio Bay, Victoria, Australia[J]. Mar Pollut Bull, 1995(30): 543-554.
  • 3Lebo JA, Gale RW, Petty JD, et al. Use of the semipermeable membrane device ( SPMD) as an in situ sampler of water borne bioavailable PCDD and PCDF residues at subpart - per - quadrillion concentrations [J]. Environ Sci and Technol,1995,29:2886-2892.
  • 4Cailleaud K, Forget -Leray J, Souissi S, et al. Seasonal variations of hydrophobic organic contaminant concentrations in the water-column of the Seine Estuary and their transfer to a planktonic species Eurytemora affinis ( Calanoida, copepode ). Part I: PCBs and PAHs[J]. Chemosphere, 2007, 70: 270--280.
  • 5Utvik TIR, Durell GS, Johnsen S. Determining produced water originating polycyclic aromatic hydrocarbons in North Sea waters: Comparison of sampling techniques [ J]. Mar Pollut Bull, 1999(38) :977-989.
  • 6Mccarthy KA, Gale RW. Evaluation of persistent hydrophobic organic compounds in the Columbia River Basin using semipermeable membrane devices[J]. Hydrol Process, 2001 ( IS): 1271-1283.
  • 7Kathleen McCarthy. Investigation of hydrophobic contaminants in an urban slough system using passive sampling - insights from sampling rate calculations [J]. Environ Monit Assess, 2008, 145:31-47.
  • 8Jingxian Wang, Yonghong Bi, Gerd Pfister, et al . Determination of P AH, PCB and OCP in water from the Three Gorges Reservoir accumulated by semipermeable membrane devices (SPMD )[J]. Chemosphere, 2009, 75: 1119-1127.
  • 9Huckins IN, Petty JD, Lebo JA, et al. Development of the permeability/performance reference compound (PRC) approach for in situ calibration of semipermeable membrane devices(SPMDs)[J]. Environ Sci and Technol, 2002, 36:85- 9l.
  • 10王毅,刘季昂,马梅,王春霞,王子健.半渗透膜采样技术监测城市污水处理流程中的难降解有毒有机污染物[J].中国环境监测,1999,15(3):1-4. 被引量:10

二级参考文献21