摘要
采用过氧化氢,柠檬酸和氨水溶样,电感耦合等离子体发射光谱仪测定三氧化钼中低含量钨。建立了一种方便快捷准确测定三氧化钼中低含量钨的新方法。采用本方法测定实验室样本中钨,与四苯砷氯盐酸盐-硫氰酸盐光度法测定的结果吻合较好,精密度为1.8%-4.4%,加标回收率在97%-110%之间。
In this work, the molybdenum trioxide samples were dissolved by hydrogerI peroxide, citric acid and ammonia and the concentration of tungsten was determined by inductively coupled plasma-optical emission spectrometry. A novel method for the determination of tungsten in molybdenum trioxide by inductively coupled plasma-optical emission spectrometry was developed. Results of tungsten were in agreement with the val- ues which obtained by tetra-arsenic chloride hydrochloride- thiocyanate spectrophotometry method. The relative standard deviation (RSD) was 1.8% - 4. 4% , and the recoveries were in the range of 97% - 110%.