期刊文献+

软土地区竖直地埋管换热器回填材料性能研究 被引量:5

THE PERFORMANCE OF BACKFILL MATERIALS FOR VERTICAL GROUND HEAT EXCHANGER IN SOFT CLAY AREA
下载PDF
导出
摘要 竖直地埋管换热器回填材料性能对地源热泵换热系统的换热能力有直接影响。对不同配比的水泥基回填材料的导热性能进行测试分析。对不同配比的膨润土基回填材料的导热性能、抗渗性能以及充填性能进行测试分析。得出不同配比下导热系数、渗透系数、析水率的变化曲线,建立膨润土基回填材料导热系数与加压养护压力关系式及膨润土基回填材料水灰比与析水百分比关系式。 The performance of the vertical ground heat exchanger makes a direct impact on the heat exchanging ability of the ground-source heat pump system. In this paper the conductivity of the different proportion cement-based backfill materials was tested. And the thermal conductivity, anti-permeability, backfill property of the different proportion bentonite-based backfill materials are tested. The curve of the thermal conductivity, anti-permeability and condensate water rate are derived and the relation formulas for the thermal conductivity and pressure, the water-cement and condensate water rate of betonies-based backfill materials are sated up.
出处 《太阳能学报》 EI CAS CSCD 北大核心 2014年第3期534-539,共6页 Acta Energiae Solaris Sinica
关键词 地埋管换热器 回填材料 导热性能 抗渗性能 充填性能 vertical ground heat exchanger backfill materials thermal conductivity anti- permeability backfill property
  • 相关文献

参考文献15

二级参考文献60

  • 1刘冬生,孙友宏,庄迎春.增强地源热泵竖直埋管地下换热器换热性能的研究[J].吉林大学学报(地球科学版),2004,34(4):648-652. 被引量:25
  • 2高祖锟.用于供暖的土壤-水热泵系统[J].暖通空调,1995,25(4):9-12. 被引量:21
  • 3[1]Yan Gu, Dennis L. O′Neal. Modeling the effect of backfills on U-Tube ground coil performance [J]. ASHRAE Trans.,1998, 104 (2): 46-54.
  • 4NINA MATTSSON, GILBERT STEINMANN, LYESSE LAI.OUI. Advanced compact device for the in situ determination of geothermal characteristics of soils [J]. Energy and Buildings, 2008,40: 1344-1352.
  • 5ESEN H, INALLI M. In situ thermal response test for ground source heat pump system in elazi{dotless}g, Turkey[J].Energy and Buildings, 2009, 41 (4):395- 401.
  • 6KAVANAUGH S P. Field tests for ground thermal properties Inethods and impact on ground source heat pump design[J].ASHRAE Transactions, 1992,98 (2) : 607-615.
  • 7KAVANAUGH S P. Field test s for ground thermal properties methods and impact on ground-source heat pumps[J]. ASHRAETrans, 1998, 104 (2) :347- 355.
  • 8HAKAN DEMIR, AHMET KOYUN, GALIP TEMIR. Heat transfer of horizontal parallel pipe ground heat exchanger and experimental verification [J]. Applied Thermal Engineering, 2009, 29 (2/3) : 224-233.
  • 9SHARQAWY M H, MOKHEIMER E M, HABIB M A. Energy, exergy and uncertainty analyses of the thermal response test for a ground heat exchanger[J]. International Journal of Energy Research,2009, 33(6) : 582 592.
  • 10MOGENSEN P. Fluid to duct wall heat transfer in duct system heat storages[C]//Proceedings of the International Conference on Subsurface Heat Storage in Theory and Practice. Swedish Council for Building Research, 1983.

共引文献105

同被引文献70

引证文献5

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部