All-on-4种植体参数对周围骨应力影响的三维有限元分析 被引量:12

A three-dimensional finite element analysis of stress distribution in peri-implant bone with All-on-4 implant with various parameters
下载PDF
导出
摘要 目的:运用三维有限元法探讨All-on-4远中种植体倾斜角度及悬臂梁长度变化对植体周围骨组织应力的影响。方法:对无牙颌下颌骨标本进行CT扫描,应用Mimcs、Geomagic、Unigraphics、HyperMesh等建模软件建立4个远中种植体不同倾斜角度对应不同悬臂长度的All-on-4种植体有限元模型。150 N垂直静载荷施于右侧悬臂梁末端,用Abaqus软件分析种植体周围骨组织应力。结果:远中种植体倾斜0°悬臂长度为19.5 mm,近、远中种植体周围皮质骨应力峰值分别为25.526MPa和83.026 MPa。当远中种植体分别倾斜15°、30°、45°时,悬臂长度相应减小为17.2、13.3、9.8 mm,与倾斜0°模型相比,种植体远中周围皮质骨应力分别减少12.4%、35.6%、53.1%,种植体近中周围皮质骨应力分别减少13.6%、36.3%、40.2%。结论:从应力分析角度看,All-on-4远中种植体倾斜角度大悬臂梁短的设计优于倾斜角度小悬臂梁长的设计。 Objective:To investigate the stress distribution in peri-implant bone with All-on-4 implant with various parameters by three-dimensional finite element method.Methods:An edentulous mandibular specimen was scanned by CT Mimcs.Geomagic,Uni-graphics,HyperMesh modeling software were used to establish All-on-4 implant finite element models with different inclination angles and corresponding cantilever lengths.1 50 N vertical static load was applied at the right end of the cantilever,peri-implant bone stress was analysed using Abaqus software.Results:When the distal implant inclined 0°with cantilever length of 1 9.5 mm,the peak stress in peri-implant cortical bone at the mesial and distal side was 25.526 MPa and 83.026 MPa respectively.When the distal implant in-clined 1 5°,30°and 45°with the cantilever length of 1 7.2 mm,1 3.3 mm and 9.8 mm,the stress in perio-implant cortical bone at distal side of the implant reduced by 1 2.4%,35.6% and 53.1 %,that at mesial side of the implant reduced by 1 3.6%,36.3% and 40.2%,respectively.Conclusion:From the perspective of the stress analysis,the design of All-on-4 distal implant with large incli-nation angle and short cantilever is superior to that with small inclination angle and long cantilever.
出处 《实用口腔医学杂志》 CAS CSCD 北大核心 2014年第2期193-197,共5页 Journal of Practical Stomatology
关键词 All—on-4 应力 有限元分析 All- on-4 Stress Finite element analysis
  • 相关文献

参考文献17

  • 1Babbush CA, Kutsko GT, Brokloff J. The all-on-four imme- diate function treatment concept with Nobel Active implants: A retrospective study [ J ]. J Oral Implantol, 2011,37 (4) : 431 -445.
  • 2Crespi R, Vinci R, Cappar6 P, et al. A clinical study of e- dentulous patients rehabilitated according to the " all on four" "immediate function protocol [ J]. Int J Oral Maxillofac Implants ,2012,27 (2) :42~ - 434.
  • 3Bevilaequa M, Tealdo T, Pera F, et al. Three-dimensional fi- nite element analysis of load transmission using different im- plant inclinations and cantilever lengths [ J ]. Int J Prosth- odont,2008,21 (6) : 539 - 542.
  • 4Zampelis A, Rangert B, Heijl L,et al. Tilting of splinted im- plants for improved prosthodontic support: A two-dimension- al finite element analysis [ J ]. J Prosthet Dent, 2007,97 ( 6 Suppl) :$35 -43.
  • 5苏忠平,何黎升,白石柱,商洪涛,毛赢,耿谦.应用Mimics和HyperMesh软件建立人体下颌骨三维有限元模型[J].实用口腔医学杂志,2012,28(2):192-195. 被引量:17
  • 6Boccaccio A, Lamberti L, Pappaletere C, et al. Mechanical behavior of an osteotomized mandible with distraction ortho- dontic devices [ J ]. J Biomech, 2006,39 ( 15 ) :2907 - 2918.
  • 7Takahashi T, Shimamura I, Sakurai K. Influence of number and inclination angle of implants on stress distribution in mandibular cortical bone with All-on-4 Concept [ J]. J Prosthodont Res, 2010,54 (4) : 179 - 184.
  • 8王惠芸.中国人牙体形态测量[J].中华口腔科杂志,1959,7(3):47-53.
  • 9李德华,刘宝林,陈小文.68副中国成人离体下颌骨颏部的测量[J].实用口腔医学杂志,1995,11(2):112-114. 被引量:4
  • 10Sertgtiz A,Giivener S. Finite element analysis of the effect of cantilever and implant length on stress distribution in an im- plant- supported fixed prosthesis [ J ]. J Prosthet Dent, 1996, 76(2) :165 - 169.

二级参考文献14

  • 1赵峰,高勃,刘震侠,胡江峰.Dicom标准和Mimics软件辅助建立下颌骨三维有限元模型[J].西南国防医药,2005,15(5):479-481. 被引量:53
  • 2陈琼.三维有限元建模方法的研究现状[J].口腔医学,2006,26(2):154-155. 被引量:34
  • 3顾卫平,殷新民,谢兰生,黄明智,徐作文.利用中国可视化人体图像建立颞下颌关节的三维有限元模型[J].实用口腔医学杂志,2006,22(6):771-774. 被引量:10
  • 4于开平.Hypermes的入门与精通[M].北京:科学出版社,2005:1-445.
  • 5Vollmer D,Meyer U,Joos U,et al.Experimental and finiteelement study of a human mandible[J].J CraniomaxillofacSurg,2000,28(2):91-96.
  • 6Boccaccio A,Lamberti L,Pappalettere C,et al.Mechani-cal behavior of an osteotomized mandible with distraction or-thodontic devices[J].J Biomech,2006,39(15):2907-2918.
  • 7Escott EJ,Rubinstein D.Free DICOM image viewing andprocessing software or your desktop computer:What's availa-ble and what it can do for you[J].Radiographics,2003,23(5):1341-1357.
  • 8Castao MC,Zapata U,Pedroza A,et,al.Creation of athree-dimensional model of the mandible and the TMJ in vivoby means of the finite element method[J].Int J ComputDent,2002,5(2-3):87-99.
  • 9Kavanagh EP,Frawley C,Kearns G,et al.Use of finiteelement analysis in presurgical planning:Treatment of mandib-ular fractures[J].Ir J Med Sci,2008,177(4):325-331.
  • 10Buyukkurt MC,Tozoglu S,Yavuz MS,et al.Simulation ofsinus floor augmentation with symphysis bone graft usingthree-dimensional computerized tomography[J].Int J OralMaxillofac Surg,2010,39(8):788-792.

共引文献19

同被引文献104

引证文献12

二级引证文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部