基于差分图校正环状伪影的自动阈值选取研究

Research on Automatic Threshold Selection in Ring Artifact Correction Based on Differential Figure
下载PDF
导出
摘要 CT图像环状伪影是影响CT图像质量的重要伪影之一。在重建图像基础上使用低通滤波减除环状伪影是环状伪影校正方法中的主要手段。而在这个过程中通过阈值隔断差值图中的边界信息是直接影响校正结果的重要操作。通过模拟数据的研究,提出一种自动选取阈值的新方法,并在实际CT数据中进行验证。该方法在保证图像细节分辨率的情况下环状伪影得到有效抑制,图像质量获得显著提高。 Ring artifact is one of the important artifacts affect CT image quality. Using low pass filter to reduce ring artifact based on reconstruction image is the main tool in correction methods. Cutting off the boundary information in difference image by a threshold will effect the cor-rect result directly. Presents a new method of selecting threshold automatically based on the study of simulated data, and verifies it in ac-tual CT data. Ring artifact has been effectively suppressed under the circumstance to ensure image detail resolution, image quality is sig-nificantly improved.
作者 王海浪
机构地区 东南大学
出处 《现代计算机》 2014年第6期49-52,61,共5页 Modern Computer
关键词 环状伪影 低通滤波 自动阈值选取 Ring Artifact Low Pass Filter Automatic Threshold Select
  • 相关文献

参考文献5

  • 1李俊江,胡少兴,李保磊,杨民.CT图像环状伪影校正方法[J].北京航空航天大学学报,2007,33(11):1378-1382. 被引量:22
  • 2Sijbers J, Postnov A. Reduction of Ring Artifacts in High Resolution Micro-CT Reconstructions[J]. Physics in Medicine and Biology, 2004, 49(14): N247.
  • 3Yang J, Zhen X, Zhou L, et al. Geometric Correction for Cone-Beam CT Reconstruction and Artifacts Reduction[C]. Bioinformatics and Biomedical Engineering, 2008. ICBBE 2008. The 2nd International Conference on. 1EEE, 2008:2386-2389.
  • 4Prell D, Kyriakou Y, Kalender W A. Comparison of Ring Artifact Correction Methods for Flat-Detector CT[J]. Physics in Medicine and Biology, 2009, 54(12): 3881.
  • 5Wang Z, Sheikh H R, Bovik A C. No-Reference Perceptual Quality Assessment of JPEG Compressed Images [C]. Image Processing. 2002. Proceedings. 2002 International Conference on. IEEE, 2002, 1:I--477-I-480 vol. 1.

二级参考文献8

  • 1李俊江,路宏年,李保磊.X射线图像增强器像元响应不一致性的分析及校正[J].光学技术,2006,32(5):779-781. 被引量:10
  • 2Nagarkar V, Guptar T, Klugeman Y. Structured CsI(T1) scintillator X-ray imaging applications [J]. IEEE Transactions on Nuclear Science, 1998,45 ( 3 ) :492 - 496
  • 3Varian Medical Systems. PaxScan flat panel imagers 2520,4030A communications manual[ M ]. North Charleston : Varian Medical Systems, 2004 : 64 - 65
  • 4Kowalski G. Suppression of ring artifacts in CT fan-beam scanners[J]. IEEE Transon Nucl Sci, 1978, 25(5):1111 -1116
  • 5Davis G R, Elliott J C. X-ray microtomography scanner using time-delay integration for elimination of ring artifacts in the reconstructed image[J]. Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 394(1/2):157 -162
  • 6Raven C. Numerical removal of ring artifacts in microtomography [ J]. Review of Scientific Instruments, 1998,69 ( 8 ) : 2978 - 2980
  • 7Rivers M. Tutorial introduction to X-ray computed microtomography data processing[ EB/OL]. Chicago:University of Chicago, 1998. http://www-fp.mcs. anl. gov/xray-emt/rivers/tutorial.html
  • 8Mantani A, Terakawa K. Artifact reduction filtering method for CT images [ C ]//Annual International Conference of the IEEE Engineering in Medicine and Biology-Proceedings. Piscataway, NJ:IEEE ,2002,2 : 1035 - 1036

共引文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部