加温日光温室保温层苯板厚度优化

Optimization on Thickness of Insulation Layer of Heated Solar Greenhouse
下载PDF
导出
摘要 为降低加温日光温室生产成本,提高经济效益,对日光温室保温层苯板进行节能优化。研究在确定能够满足使用要求的保温层苯板厚度基础上,引入了核心经济参数f,客观反映节能效果与建造成本投入的的关系,提供了以乌鲁木齐为例的详细计算方法。结果表明,核心经济参数f存在最大值,并且可以通过材料的性能与市场的关系确定,通过计算可知,乌鲁木齐地区加温日光温室保温层厚度最佳值为0.082 m。 In order to reduce the heating cost of solar greenhouse and improve economic efficiency, we optimized the insulation layer's thickness of heated solar greenhouse. We introduced the core economic parameters f to reflect the relationship between energy saving efficiency and construction investment, and we provided a detailed calculation method by taking Urumqi as an example. The results showed that, the core economic parameters f had maximum value, and the optimum thickness of the insulation layer of solar greenhouse was 0.082 m in the region of Urumqi.
出处 《长江蔬菜》 2014年第6期47-49,共3页 Journal of Changjiang Vegetables
基金 自治区"十二五"重大专项新疆设施农业产业高效持续发展关键技术研究与示范(201130104-2-1)
关键词 加温温室 节能优化 保温层 墙体厚度 Heated solar greenhouse Energy-saving optimization Insulation layer Thickness