摘要
在磷酸介质和加热条件下,痕量铑(Ⅲ)能灵敏地催化高碘酸钾氧化二安替比林对二甲氨基苯基 甲烷(DAMAM)的显色反应。研究了该催化反应的最佳实验条件及动力学参数,建立了一种动力学光度 法测定痕量铑的新方法。方法的线性范围为0~84μg/L;检出限为6.20×10-7g/L。催化反应的表观活 化能为89.03kJ/mol,表观速率常数为2.51×10-4/s,反应终止后至少稳定6h。本法已用于某些催化剂中 铑的测定,其相对标准偏差为2.7%~3.2%;标准加入回收率为98.2%~103.2%。
A kinetic method for the determination of trace rhodium based on the catalytic effect of Rh on the oxidative color reaction of diantipyryl-(p-dimethylamino) -phenylmethane (DAMAM) with potassium periodate in the H3PO4 medium and hot water bath was established. The optimum comdition and kinetic parameters of this reactionhis were studied in detail. The linear range of the determination was 0 ~ 80 μg/L, and the detection limit was 6.20× 10~7 g/L. The apparent activation energy of catalytic reaction was found to be 89.03kJ/mol,rate constant was 2.51 ×10-4/s. The system was stable at least at least 6h. The method has been applied to determine trace rhodium in some catalyst samples with the relative standard deviation of 2.7% ~ 3.2% (n=6) and recovery of 98.2% ~ 103.2% (n=5).
出处
《分析化学》
SCIE
EI
CAS
CSCD
北大核心
2001年第2期208-211,共4页
Chinese Journal of Analytical Chemistry