导出
摘要 目的探讨超声联合钼靶X线在乳腺肿块诊断中的应用价值。方法乳腺肿块患者94例中恶性肿瘤56例,良性肿瘤38例,均行超声、钼靶X线检查,与手术组织病理结果进行对照,分析超声、钼靶X线单独及联合诊断乳腺肿块的价值。结果超声、钼靶X线及二者联合诊断乳腺肿块的准确性分别为69.15%、71.28%、91.49%,敏感性分别为80.36%、82.14%、94.64%,特异性分别为52.63%、55.26%、86.84%,超声联合钼靶X线诊断乳腺肿块的准确性、敏感性、特异性高于超声或钼靶X线单独检查(P<0.05);二者联合诊断的AUC大于超声或钼靶X线单独检查(P<0.05)。结论超声与钼靶X线联合检查可提高乳腺体肿块诊断的准确性。 Objective To investigate the clinical value of ultrasonography plus molybdenum target X-ray to the diagnosis of breast tumors. Methods Ninety-four patients with breast tumors including 56 patients with malignant tumor and 38 patients with benign tumor, underwent ultrasonography and/or molybdenum target X ray, and compared with the histopathoiogical results to analyze the values of ultrasonography, molybdenum target X-ray, and ultrasonography plus molybdenum target X-ray to the diagnosis of breast cancer. Results The diagnosis accuracies of ultrasonograpby, molybdenum target X-ray and ultrasonography plus molybdenum target X ray were 69.15%, 71. 28%and 91.49%. The sensitivities were 80.36%, 82.14% and 94.64%. The specificities were 52. 63%, 55.26% and 86.84%. The accuracy, sensitivity and specificity of ultrasonography plus molybdenum target X-ray were significantly higher than those of either ultrasonography or molybdenum target X-ray (P〈0.05). The AUC of ultrasonography plus molybdenum target X-ray was larger than that of either ultrasonography or molybdenum target X-ray (P〈0.05). Conglusions Combined detection of ultrasonography and molybdenum target X-ray can improve the diagnosis accuracy for breast tumors.
作者 张春霞 杨丽
出处 《中华实用诊断与治疗杂志》 2014年第4期402-404,共3页 Journal of Chinese Practical Diagnosis and Therapy
关键词 乳腺肿块 超声 钼靶X线 Breast tumor ultrasonography molybdenum target X-ray
  • 相关文献

参考文献7

  • 1Kremer M E, Downs-Holmes C, Novak R D, et al. Neglecting to screen women between the ages of 40 and 49 years with rnammography: what is the impact on breast eancer diagnosis? [J]. AJRAmJRoentgenol,2012,198(5):1218-1222.
  • 2American College of Radiology (ACR). ACR BI RADS- mammography[M]. 4th ed//ACR Breast Imaging Reporting and Data System, Breast Imaging Atlas. Reston: American College of Radlology,2003 : 1.
  • 3李景刚,王辉,吴社谋,张保山.超声引导下乳腺肿块穿刺活检60例分析[J].中华实用诊断与治疗杂志,2008,22(7):534-534. 被引量:4
  • 4刘英姿,吴秀花.BI-RADS分级超声诊断乳腺病变应用价值[J].中华实用诊断与治疗杂志,2010,24(6):588-589. 被引量:23
  • 5王雁,郭晓霞,黄洁.彩色多普勒血流成像在乳腺肿瘤中的价值[J].中华实用诊断与治疗杂志,2012,26(6):571-572. 被引量:15
  • 6Onitilo A A, Engel J M, Liang H, et al. Mammography utilization: patient characteristics and breast cancer stage at diagnosis[J]. AJR Am J Roentgenol, 2013,201 (5) : 1057-1063.
  • 7Ciatto S, Houssami N, Bernardi D, et al. Integration of 3D digital mammography with tomosynthesis for population breast- cancer screening (STORM) : a prospective comparison study[J]. Lancet Oncol,2013,14(7) :583-589.

二级参考文献12

共引文献36

同被引文献127

引证文献17

二级引证文献166

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部