摘要
通过分析N600-24.2/566/566超临界汽轮发电机组的特点,在进行各项准备的前提下,分别对其进行了50%和100%的甩负荷试验,考核检验汽轮发电机组调节系统动态特性及主、辅机设备对甩负荷恶劣工况的适应能力,并通过风险控制圆满完成甩100%负荷。
By analyzing the characteristics of N600-24.2/566/566 supercritical steam turbine generator sets, the load rejection test of 50% and 100% are respectively carried on the premise of the preparation. The dynamic performance of steam turbine generator set regulating system, the adaptability of main and auxiliary equipment to bad working condition of load rejection are examined. The 100% load rejection is completed successfully by the risk control.
出处
《电气传动自动化》
2014年第1期23-27,共5页
Electric Drive Automation
关键词
超临界汽轮机
直流炉
甩负荷
旁路
supercritical steam turbine
DC furnace
load rejection
bypass