Dosimetric evaluation of a beam matching procedure

一套束流匹配程序的剂量学评价(英文)
下载PDF
导出
摘要 Objective: The dosimetric characteristics for linear accelerators with the same model, and nominal energy are known to be very similar, as long as the machines are unaltered from the manufacturer's original specifications. In this preliminary study, a quantitative investigation of the similarity in the basic photon and electron dosimetry data from the Siemens Oncor linear accelerators at our hospital(Children's Cancer Hospital, Cairo, Egypt) was reported. Methods: The output factor(OF), wedge factors(WF), percentage depth dose(PDD), and beam profile for the 6 and 10 MV photon beams were measured. Results: The measured output factors varied by less than about 1% for each field size. The difference between the maximum and minimum PDD values at each depth was less than about 1%. The difference between the beam flattnes and symetry was no more than 1% at all off-axis distances. For electron the results showed that the PDD, OF, and the beam profiles were matched within 1% differences. Conclusion: These results strongly suggest that it is feasible to establish one reference photon and electron dosimetry data set for the two machines and nominal energies.
出处 《The Chinese-German Journal of Clinical Oncology》 CAS 2014年第2期89-93,共5页 中德临床肿瘤学杂志(英文版)
关键词 beam matching dosimetric verification linear accelerator 剂量学特性 直线加速器 评价 程序 测定数据 PDD 光子束
  • 相关文献

参考文献13

  • 1Bhangle JR, Narayanan VK, Kumar NK, et al. Dosimetric analysis of beam-matching procedure of two similar linear accelerators. J Med Phys, 2011,36: 176-180.
  • 2Sjostrom D, Bjelkengren U, Ottosson W, et al. A beam-matching concept for medical linear accelerators. Acta Oncol, 2009, 48: 192-200.
  • 3Chetty IJ, Curran B, Cygler JE, et al. Report of the MPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning. Med Phys, 2007, 34: 4818-4853.
  • 4Mijnheer B, Olszewska A, Fiorino C, et al. Quality assurance of treatment planning systems. Practical examples for non-IMRT photon beams. Estro: Booklet 7,2004.
  • 5Venselaar J, Welleweerd H, Mijnheer B. Tolerances for the accuracy of photon beam dose calculations of treatment planning systems. Radiother Oncol, 2001,60: 191-201.
  • 6Ahnesjo A, Aspradakis MM. Dose calculations for external photon beams in radiotherapy. Phys Med Bioi, 1999,44: R99-R155.
  • 7Goitein M. Nonstandard deviations. Med Phys, 1983, 10: 709-711.
  • 8Goitein M. Calculation of the uncertainty in the dose delivered during radiation therapy. Med Phys, 1985, 12: 608-612.
  • 9Hrbacek J, Depuydt T, Nulens A, et al. Quantitative evaluation of a beam-matching procedure using one-dimensional gamma analysis. Med Phys, 2007, 34: 2917-2927.
  • 10Watts RJ. Comparative measurements on a series of accelerators by the same vendor. Med Phys, 1999,26: 2581-2585.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部