期刊文献+

计及不确定因素影响的交直流系统可用输电能力评估 被引量:4

Evaluation of Available Transmission Capacity for Hybrid AC/DC System Considering The Uncertain Factors
下载PDF
导出
摘要 提出并建立了计及不确定因素影响的交直流混合系统可用输电能力优化计算模型,在综合考虑交直流混合电力系统运行的各种不确定因素基础上,量化分析各种不确定因素对系统运行可靠性的影响,采用蒙特卡罗方法对交流和直流系统的不确定性因素进行抽样,借助于内点法对可用输电能力优化模型进行求解。以IEEE-30节点系统和扩展的IEEE-30节点交直流混合系统为例对本文所提方法进行仿真计算,算例分析表明该方法的合理性和有效性。 This paper proposes and establishes the optimal calculation model of available transfer capability for AC/DC hybrid system considering uncertainties. This paper proposes and establishes the optimal calculation model of available transfer capability for AC/DC hybrid system considering uncertainties. Based on uncertain factors for AC/DC hybrid power system, quantitative analysis of uncertain factors on the system reliability, Monte Carlo method is used for sampling the uncertainties of AC and DC system, with using Interior point method to solve the optimization model of available transfer capability. A case study of IEEE-30 bus system and extended IEEE-30 bus AC/DC hybrid power system demonstrates the rationality and validity of strategies pro-posed in this paper.
出处 《东北电力大学学报》 2014年第1期52-58,共7页 Journal of Northeast Electric Power University
关键词 可用输电能力 交直流混合系统 内点法 电网规划 非序贯蒙特卡洛 Available Transfer Capability Hybrid AC-DC systems Primal-dual Interior-point method Power Grid Planning Monte-Carlo
  • 相关文献

参考文献14

二级参考文献89

共引文献233

同被引文献44

引证文献4

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;