某电站锅炉过热器管老化状态评估 被引量:2

Aging Condition Assessment of Superheater Tube of Subcritical Boiler
下载PDF
导出
摘要 对某电厂已经运行约1.68×105 h的亚临界机组低温过热器管进行材质性能试验研究,测定了该受热面管的拉伸强度和高温蠕变性能,最后采用基于连续损伤力学方法对其进行老化状态评估,评估结果表明,在规定温度和压力下,可继续运行73 000 h左右. The experimental study of 12CrlMoV steel for the power plant was carried out by analyzing the tensilestrength, microhardness and high temperature creep performance test. Finally,the aging condition of the heating surface tube was assessed using the finite ele- ment method based on the continuous damage mechanics theory. The result indicates the su- perheater tube still serve about more than 73,000 hours, under the specified temperature and pressure
出处 《锅炉技术》 北大核心 2014年第2期60-62,共3页 Boiler Technology
关键词 亚临界锅炉 过热器管 状态评估 12CrlMoV supercritical boiler superheater tube aging condition assessment 12Cr1MoV