摘要
将聚合氯化铝铁(PAFC)与聚丙烯酰胺(CPAM)复配用于处理城市生活污水,絮凝搅拌试验得出最佳的应用条件为:PAFC投加量30 mg/L,CPAM为4 mg/L,pH为6~8.此条件下具有沉降速度快、除浊效率高等特点.聚合氯化铝铁与聚丙烯酰胺复配的絮凝性能比聚合氯化铝铁更加优异.
A flocculant was prepared with polyaluminum ferric chloride (PAFC) and polyacrylamide (CPAM) and was used to treat urban domestic sewage. The optimum synthesis and application conditions were identified in flocculation and agitation tests : addition of PAFC : 30 mg/L, addition of CPAM : 4 mg/L, pH value: 6 to 8. Both the settling velocity and the turbidity removal efficiency were high at such conditions. The flocculant prepared with PAFC and CPAM is better than PAFC in flocculation performance.
出处
《精细石油化工进展》
CAS
2014年第2期49-51,共3页
Advances in Fine Petrochemicals
关键词
复配絮凝剂
聚合氯化铝铁
聚丙烯酰胺
絮凝搅拌
污水处理
flocculant
polyaluminum ferric chloride
polyacrylamide
flocculation and agitation
sewage treatment