摘要 对谐振式科里奥利质量流量计的基本敏感机理进行了论述 .基于典型的U型管敏感结构 ,建立了谐振式直接质量流量计的数学模型 ,给出了检测质量流量的信号解算模型 ,设计了一种信号解算电路并研制了相应的样机 .实测结果表明 :所研制的信号检测电路的测量误差小于 0 .1 % ,具有一定的实用价值 ,为样机研制提供了具有一定参考意义的理论和实验研究结果 . The essential sensing mechanism was investigated for the resonant Coriolis direct massflow meter in detail.The mathematical model of the resonant direct massflow meter was established,based on a typical U type tube resonant sensing structure.The output signal calculating model was provided for the above massflow meter based on measuring the amplitude ratio.A signal processing circuit prototype was designed and developed by making use of MCS 51 type micro processor,based on the above output signal calculating model.The testing results show that measuring error is less than 0.1%F.S.for the above developed processing circuit prototype.The theoretical and experimental results obtained here are of practical significance for developing the Coriolis resonant direct massflow meter.
出处 《北京航空航天大学学报》 EI CAS CSCD 北大核心 2000年第6期653-655,共3页 Journal of Beijing University of Aeronautics and Astronautics
基金 国家自然科学基金资助项目(69674029)
关键词 质量流量计 传感器 检测 科氏效应 mass flow meters sensors measuring Coriolis effect
  • 相关文献

参考文献4

二级参考文献3

  • 1樊尚春 刘广玉.载有流体的弹性管频率特性的有限元分析.中国航空科技报告HK97014[M].北京:中国航空工业总公司,1997..
  • 2刘广玉,几种新型传感器.设计和应用,1988年
  • 3樊尚春,中国航空科技报告,HK97014,1997年