期刊文献+

CdS量子点-高锰酸钾-鲁米诺化学发光体系测定对乙酰氨基酚 被引量:5

CdS QDs-KMnO_4-Luminol Chemiluminescence System for Determination of Acetaminophen
下载PDF
导出
摘要 基于对乙酰氨基酚在碱性介质下对CdS量子点-高锰酸钾-鲁米诺化学发光体系强烈的抑制作用,建立了对乙酰氨基酚的流动注射化学发光测定方法。通过正交试验优化的测试条件为:5.0×10-3 mol·L-1 NaOH、1.0×10-5 mol·L-1 KMnO4、6.0×10-4 mol·L-1CdS量子点、5.0×10-4 mol·L-1鲁米诺、样品(标准品或水)的体积比为1∶1∶4∶2∶1;方法对对乙酰氨基酚的线性范围为1.0×10-8~1.0×10-4 mol·L-1,相关系数R为0.9991,检出限为6.0×10-10 mol·L-1;对1.0×10-6 mol·L-1的对乙酰氨基酚溶液平行测定11次,其相对标准偏差(RSD)为0.6%。该方法可应用于药物中对乙酰氨基酚含量的测定。 A sensitive flow injection chemiluminescence (FL-CL) method for the determination of acetaminophen was developed. The method was based on that acetaminophen could inhibit the CL reaction of CdS quantum dots-luminol-potassium permanganate in sodium hydroxide. The test conditions were optimized by orthogonal test. The volume ratio of 5.0 × 10-3 mol. L-1 NaOH, 1. 0 × 10 -5 mol. L-1 KMnO4,6.0 × 10-4 mol .L-1 CdS QDs, 5.0 × 10-4 mol.L-1 luminol and the samples (standard or water) was 1:1:4:2:1. The detection limit of the method was 6. 0×10-10mol.L-1. The linear range for acetaminophen was 1.0× 10-8-1.0× 10-4mol.L-1. The relative standard deviation was 0.6% for 1.0 ×10-6mol . L-1 acetaminophen in 11 repeated measurements. This method could be applied to the determination of acetaminophen in medicament sample.
出处 《分析科学学报》 CAS CSCD 北大核心 2014年第2期231-234,共4页 Journal of Analytical Science
基金 陕西省科技统筹创新工程项目(地方重大专项)(No.2012KTDZ02-02) 商洛学院服务地方经济社会发展专项资助项目(11SKY-FWDF004)
关键词 化学发光 CDS量子点 高锰酸钾 鲁米诺 对乙酰氨基酚 Chemiluminescence CdS quantum dots Potassium permanganate Luminol Acetaminophen