摘要 采用共聚焦光学结构,以高强度365nm UV-LED为激发光源,设计了一种新型UV-LED诱导荧光检测器。以荧光增白剂OB为样品,对该检测器进行了性能评价,基线噪声为0.052mV,漂移为0.094mV/h,检出限(S/N=3)达3.0×10-12g/mL,线性范围达3个数量级,日内和日间保留时间、峰高和峰面积的重现性(RSD)均小于1%(n=5);以黄曲霉毒素M1为分析对象,检出限(S/N=3)为1.8×10-10g/mL。测试结果说明该荧光检测器与商品化检测器性能相当,可用于环境、食品和生物等样品的痕量分析。 A novel high power UV-LED-induced fluorescence detector is designed with the principle of confocal optical configuration. A 365 nm UV-LED is used as the excitation light source. Using fluorescent brightener OB as the evaluation sample,the noise and drift levels of this detector are 0. 052 mV and 0. 094 mV/h, the detection limit(S/N= 3) is 3.0 × 10-12 g/mL, the linear dynamic range can reach 3 orders of magnitude and the relative standard deviations(RSD) of retention time,peak height and peak area are less than 1% (n = 5), respectively. When aflatoxin M1 is used as the sample, the detection limit(S/N=3) is 1.8 × 10-10g/mL detected by a high performance liquid chromatograph(HPLC) with the proposed detector. The testing results illustrate that the UV-LED-induced fluorescence detector exhibits similar performances compared with the fluorescence detector, which is applicable for trace sample analysis of environment, foodstuff and biology.
出处 《分析科学学报》 CAS CSCD 北大核心 2014年第2期269-272,共4页 Journal of Analytical Science
基金 国家重大科学仪器设备开发专项(No.2012YQ12004401 2012YQ12004403) 国家自然科学基金(No.51242001)
关键词 LED诱导荧光检测器 共聚焦 荧光增白剂OB 黄曲霉毒素M1 LED-Induced fluorescence detector Confocal Fluorescent brightener OB Aflatoxin M1
  • 相关文献

参考文献15

  • 1GUAN Ya-feng(关亚风),XU Jing(徐静),XIONG Yan(熊艳),CHEN Shi-heng(陈士恒).The Conference Pro-ceedings of 19'h National Symposium and Exhibition Chromatography of China(第十七届全国色谱学术报告会及仪器展览会会议论文集)[C],2009:37.
  • 2徐静,熊艳,陈士恒,关亚风.发光二极管诱导荧光检测器[J].化学进展,2009,21(6):1325-1334. 被引量:7
  • 3Marlene L, Verena P, Clara F, Francois C. Electrophoresis[J],2005,26 (13) : 2608.
  • 4YANG Bing-cheng(杨炳成),GUAN Ya-feng(关亚风),TAN Feng(谭峰),CHEN Ling-xin(陈令新).分析试验室[J],2003,22(5):89.
  • 5YANG Bing-cheng(杨炳成),TAN Feng(谭峰),CHEN Lingxin(陈令新),GUAN Ya-feng(关亚风).分析测试学报[J],2003,22(3):22.
  • 6YANG Bing-cheng(杨炳成),TAN Feng(谭峰),GUAN Ya-feng(关亚风).光谱学与光谱分析[J],2005,25(12):1995.
  • 7刘翻,于淑新,唐涛,孙元社,张维冰,李彤.新型三维可调共聚焦激光诱导荧光检测器的研制与评价[J].色谱,2011,29(9):896-900. 被引量:5
  • 8LIU Jian(刘剑),LIU Chang-chun(刘常春).仪表技术与传感器[J],2010:17.
  • 9GB/T 26792-2011. High Performance Liquid Chromatography(高效液相色谱仪)[S].
  • 10Audrey R B, Pierre N, Arnaud M,Jacques F, Bernard F, Francds C. Eleetrophoresis[J], 2012,33 : 1709.

二级参考文献122

共引文献43

同被引文献91

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部