期刊文献+

256层螺旋CT脾动脉成像中低剂量高浓度对比剂的应用研究 被引量:1

The application research of low dose and high concentration contrast medium in 256 layers spiral CT splenic artery imaging
下载PDF
导出
摘要 目的探讨256层螺旋CT脾动脉成像中应用低剂量高浓度对比剂的价值。方法选择行256层螺旋CT脾动脉成像患者100例,观察组50例采用高浓度对比剂碘普罗胺50 ml+生理盐水20 ml,对照组50例采用常规浓度对比剂碘海醇70 ml。根据CT造影图像评价两种不同浓度、不同剂量对比剂对脾动脉的显示效果。结果观察组的腹主动脉腹腔干水平、脾动脉中段及脾叶动脉CT值均高于对照组,差异有统计学意义(P<0.05)。两组脾动脉各级分支显示率比较,差异有统计学意义(P<0.05)。两组的脾动脉图像质量评分比较差异无统计学意义(P>0.05)。结论将低剂量高浓度对比剂应用于256层螺旋CT脾动脉成像中是可行的,可以获得满意的脾动脉图像,满足诊断需要,并能降低不良反应的发生率。 Objective To explore the application value of imaging splenic artery using high concentrations and low dose of contrast agent with 256-slice CT. Methods 100 cases of patients with 256-slice CT angiography were selected, high concentration of contrast agent with iopromide 50 ml and saline 20 ml were used in observation group (50 cases), conventional concentration of contrast agent with iohexol 70 ml was used in control group (50 cases).The display of the splenic artery with two different concentration and different dose of contrast agent was evaluate based on the CT image. Results CT value of abdominal aorta celiac level,the middle lobe splenic artery and splenic artery in observation group was higher than that in control group respectively,with statistical difference (P〈0.05).The rate of splenic artery branch level in two groups was compared,with statistical difference (P〈0.05).Splenic artery image quality score in two groups was compared,with no statistical difference (P〉0.05). Conclusion High concentration and low-dose contrast agent ap- plied in the splenic with multi-slice CT imaging artery can obtain satisfactory image splenic artery,meet diagnostic needs and can reduce the incidence rate of adverse reaction.
出处 《中国当代医药》 2014年第12期109-111,共3页 China Modern Medicine
基金 河北省医学科学研究重点课题计划(20110535)
关键词 多层螺旋CT 脾动脉成像 X线计算机体层摄影术 对比剂 Multi-slice spiral CT Splenic artery imaging X-ray computer tomography Contrast agent
  • 相关文献

参考文献10

二级参考文献36

共引文献63

同被引文献22

  • 1孙丛,柳澄,王道平,黄杰,王立君.多层螺旋CT低剂量高浓度对比剂腹部血管成像应用研究[J].放射学实践,2007,22(3):259-261. 被引量:18
  • 2中华医学会放射学分会对比剂安全使用工作组[Z].第2版.碘对比剂使用指南,2013.47.
  • 3Christiansen C, Pichler W J, Skotland T. Delayed allergy-like re- actions to X-ray contrast media: mechanistic considerations [ J]. Eur Radiol, 2000, 10 (12) : 1965-1975.
  • 4Webb JA, Stacul F, Thmnsen HS, et al. Late adverse reactions to intravascular iodinated contrast media [ J ]. Eur Radio1, 2003, 13(1) : 181-184.
  • 5Rihal CS, Textor SC, Grill DE, et al. Incidence and prognostic importance of at:ute renal failure after percutaneous coronary inter- vention [J]. Circulation, 2002, 105(19): 2259-2264.
  • 6Jost G, Lengsfeld P, Lenhard DC, et al. Viscosity of iodinated contrast agents during renal excretion [ J]. Eur J Radiol, 2011, 80(2) : 373-377.
  • 7Hazirolan T, Turkbey B, Akpinar E, et al. The impact of warmed intravenous contrast material on the bolus geometry of coronary CT angiography applications [ J ]. Korean J Radiol, 2009, 10(2): 150-155.
  • 8Dawson P C D G B.. X-ray contrast agents: physico-chemical properties [ J]. Oxford: Isis Medical Media Ltd, 1999. 35-46.
  • 9Wright ItS, Anderson JL, Adams CD, et al. 2011 ACCF/AHA focused update of the guidelines for the management of patients with unstable angina/non-ST-Elevation myocardial infarction ( Updating the 2007 Guideline) : a repart of the american college of cardiology foundation/american heart association task toree on practice guidelines [ J]. Circulation, 2011, 123 (18) : 2022- 2060.
  • 10Levine GN, Bates ER, Blankenship JC, et al. 2011 ACCF/ AHA/SCAlguideline for percutaneous coronmy intervention: a report of the american college of cardiology foundation/american heart association task force on practice guidelines and the society for cardiovascular angiography and intetventions [ J ]. Circula- tion, 2011, 124(23) : 574-651.

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部