摘要
通过气液在塔内的逆向流动 ,测定了液固传质系数和催化剂包内流速 .实验在常压、2 5℃下进行 ,采用内径为 5 6mm的玻璃管 ,玻璃管中的催化剂捆束总高度为 5 2 8mm .对实验数据进行回归处理 ,得到了一些关联式 ,为醋酸甲酯催化精馏水解过程的模拟提供了基础 .
The liquid-solid mass transfer coefficients and liquid flow-rate within the catalyst capsule have been measured in a countercurrent flow column by this study. The measurements were completed under the temperature 25?℃ and the normal pressure in a glass column with the diameter 56?mm and the catalyst-bed-height 528?mm. The correlations for calculation of the liquid-solid mass transfer coefficients and liquid flow-rate within the catalyst capsule were obtained by regressing the experimental data, which can be applied to simulate the catalytic distillation process for the hydrolysis of the methyl acetate.
出处
《福州大学学报(自然科学版)》
CAS
CSCD
2001年第1期90-92,共3页
Journal of Fuzhou University(Natural Science Edition)