摘要 对电外科仪器输出的高压和大电流参数进行准确检测是研制反馈式电外科仪器的基础。为此,本文研制基于PC机的输出参数测量系统,对电外科仪器输出的高压和大电流信号进行隔离感应、放大、滤波、差分信号变单端信号、有效值转换,最后通过DAQ采集卡进行模数转换,数据送入PC机中使用Labview软件进行过采样、显示和存储等处理。实验结果表明,该系统能够对电外科仪器的输出参数进行稳定测量,结果准确。因此,该系统的研制是成功的,在此基础上开发嵌入式的输出参数测量系统,能够为智能式的电外科仪器开发提供准确的反馈信息。 Accurate measurements of voltage and current from electrosurgery are the basis of development of electro- surgery with feedback function. We, therefore, developed a parameter measurement system based on PC, with high voltage and current from electrosurgery being sensed with transformers, amplified, filtered, transformed into single~ ended signals, and then into RMS signals. The root mean square (RMS) signals were transformed into digital signals through DAQ card and the data was processed in PC with Labview. The process included sampling, displaying and storage. The experiment results indicated that the measurement system could measure the output parameters from e- lectrosurgery steadily and correctly so that the development of the system has been successful. It can be the basis of development of embedded parameters measurement system and can provide accurate feedback information for intellec- tual electrosurgery.
出处 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2014年第2期421-425,共5页 Journal of Biomedical Engineering
基金 上海市科委资助项目(10441900900) 上海市教委科研创新项目资助项目(12YZ102) 上海市优秀青年教师科研专项基金(slg10020)
关键词 电外科 高压 大电流 测量 electrosurgery high voltage high current measurement
  • 相关文献

参考文献12

  • 1FRIEDRICHS D A. ERICKSON R W. GILBERTJ. A new dual current-mode controller improves power regulation in electrosurgical generators[J]. IEEE Transactions on Biomedical Circuits and Systems. 2012. 6(1) :39-44.
  • 2GOBLE C CO. Electrosurgery system and method: United States.6228081[PJ.2001-05-08.
  • 3ROBY K.VARJAN S .STASCAVAGE K. et al. A novel electrocautery device to increase coagulation rate and reduce thermal damage[CJ/ /2011 IEEE 37th Annual Northeast Bioengineering Conference (NEBEC>. Troy. NY :2011: 1-2.
  • 4DODDE R E. GE[J S. GEIGERJ D. et al. Monopolar electrosurgical thermal management for minimizing tissue damage[J]. IEEE Transactions on Biomedical Engineering. 2012.59 (1) :167-173.
  • 5PICHE N. BARRIER AS D. Minimally invasive nephronsparing surgery for unilateral Wilms tumor[n.J Pediatr Surg , 2012. 47(7) :e1-e4.
  • 6BALAGUERJ M ? UMAKANTHAN R ? LEACCHE M. er al. Minimally invasive cardiac surgery[n. Current Problems in Surgery. 2012. 49(9) :529-549.
  • 7WHAM R H. STURM T A. Automatic control system for an electrosurgical generator: United States. 7300435[PJ. 2007-11-27.
  • 8GINES D L. Electrosurgical generator with adaptive power control: United States.RE40388[PJ. 2008-06-17.
  • 9KOSS T. TAIMISTO M H. VARNER R. Impedance mediated control of power delivery for electrosurgery, World Intellectual Property Organization. WO/ 2011/119933[pJ. 2011- 09-29.
  • 10ANALOG. High Precision. Wideband RMS-to-DC Converter[EB/OLJ. (2011-02)[2012-8-20J. http://www. analog. com/ en/ special-linear-f unctions/ rms-to-dc-convertera/ ad63 7 / products/product. html.

二级参考文献11

  • 1Vrcelj B, Vaidyanathan P P. Equalization with oversampling in multiuser CDMA systems[ J]. Signal Processing, IEEE Transactions on see also Acoustics, Speech, and Signal Processing, IEEE Transactions, 2005,53(5) : 1837 - 1851.
  • 2Lim S, Apostolopoulos J, Gamal A E. Benefits of temporal oversampling in optical flow estimation[ A]. International Conference on Image Processing [ C] .IEEE Press,2004,4:2567 - 2570.
  • 3Sharif M, Gharavi-Alkhansari M, Khalaj B H. On the peak-toaverage power of OFDM signals based on oversampling [ J ]. IEEE Transactions on Communications,2003,51 (1):72- 78.
  • 4林凌,李刚.高精度采集微弱信号的方法与电路[P].中国发明专利:专利(申请)号:200610013461.8.
  • 5孙高峻.生物医学信号数据采集系统研究[D].西安:西北工业大学,2003.
  • 6A V 奥本海姆,R W 谢弗,J R 巴克.离散时间信号处理(第2版)[M].刘海棠,黄建国,译.西安:西安交通大学出版社,2001.150-167.
  • 7李刚,张丽君,林凌,何峰.结合过采样技术和锯齿成形函数的微弱信号检测[J].电子学报,2008,36(4):756-759. 被引量:20
  • 8王雪生,秦巍,凌燮亭,郑增钰.一种新型的级联并行过采样∑Δ调制器结构[J].电子学报,2000,28(2):68-71. 被引量:5
  • 9黄英,王成波.生物电及其在医学中的应用[J].中国局解手术学杂志,2002,11(4):389-390. 被引量:2
  • 10李奕,任惠茹,李刚.生物电数据采集平台的设计[J].电子质量,2003(7):95-97. 被引量:2

共引文献22

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部