摘要 超高层建筑因为其不同于一般建筑的特点,给消防给水系统的设计造成了诸如管道压力大、系统控制复杂等难题,从而给消防给水的设计提出了更高的要求。如何解决好这一难题,更好地满足人们对超高层建筑中消防给水系统设计的新要求,成为建筑界研究的新课题。通过实例分析法、比较分析法等研究方法,以某高层建筑的消防给水设计为例,提出采用高位水箱的供水方式来解决这一问题,进而对稳高压消防给水系统的技术性和经济性进行分析,认为稳高压消防给水系统的应用能够更好地解决超高层建筑消防给水系统存在的问题。 The increasing number of super high - rise buildings makes greater demands on the design of fire water supply. The differences between super high - rise buildings and general architectural features cause some problems such as the pipeline pressure, the control of complex system and so on. How to solve these problems and meet the demands on the design of fire water supply has become a new subject in the construction industry. In this paper, a real case is given to prove that the application of high level water tank is best to solve these problems based on the case analysis, the comparative analysis and other research methods. And the paper analyses the technical and eco- nomic advantages of the stabilized high -pressure fire water supply system, and draws the conclusion that the appli- cation of this system is beneficial to solve the problem of the fire water supply system in a super high - rise building.
作者 张建平
出处 《武警学院学报》 2014年第4期35-38,共4页 Journal of the Armed Police Academy
关键词 消防 稳高压消防给水系统 超高层建筑 高位消防水箱 fire stabilized high -pressure fire water supply system super high -rise building high level fire wa-ter tank