期刊文献+

提高角度法SPR检测系统分辨率的方法

Improved resolution for SPR detection systems with angular modulation
原文传递
导出
摘要 提高表面等离子共振(surface plasmon resonance,SPR)检测系统的分辨率有利于扩大其应用。该文围绕角度检测方法,从理论上阐明了检测系统的分辨率不仅随着灵敏度的增强而改善,而且随着半峰宽的变窄而提高。同时,深入分析了使用金、银以及金银膜的分辨率,明确金银膜的分辨率比金膜高,提出采用金银膜的芯片来提高系统的分辨率。以不同质量分数的NaCl溶液为介质,分别测量使用金膜和金银膜时的分辨率。实验结果表明,金膜和金银膜各自对应的分辨率为5.2×10-6 RIU(refractive index unit)和3.9×10-6 RIU,后者较前者提高1.4倍,与理论分析结果 1.6倍接近。 Improved system resolutions for surface plasmon resonance (SPR) will enable applications in more fields. This paper shows theoretically that the resolution of SPR with angular modulation is not only improved with increased sensitivity, but also with a narrower half-peak width. The resolutions with Au, Ag and Au-Ag chips show that the resolution of the Au-Ag chip is higher than that of the Au chip. Thus, the system resolution can be improved by using the Au-Ag chip. Measurements of the resolution of Au and Au-Ag chips using NaCI solutions with different mass fractions show that the Au and Au-Ag chip resolutions are 5.2 × 10^- 6 and 3.9 × 10^-6 RIU (refractive index unit). Thus, the Au-Ag chip resolution is 1.4 times higher than the Au chip, similar to the theoretical result being 1, 6 times higher.
出处 《清华大学学报(自然科学版)》 EI CAS CSCD 北大核心 2014年第2期202-206,共5页 Journal of Tsinghua University(Science and Technology)
基金 国家自然科学基金资助项目(30970757)
关键词 表面等离子共振(SPR) 系统分辨率 灵敏度 金银膜 surface plasmon resonance (SPR) system resolution sensitivity Au-Ag chip
  • 相关文献

参考文献14

  • 1Myszka D G,Rebecca L R.Implementing surface plasmon resonance biosensors in drug discovery [J].Pharmaceutical Science & Technology Today,2000,3(9):310- 316.
  • 2Workman P,Aboagye E,Balkwill F,et al.Guidelines for the welfare and use of animals in cancer research [J].British Journal of Cancer,2010,102:1555 - 1577.
  • 3Mulchan N M,Rodriguez M,Kevin O,et al.Application of a high-resolution SPR technique for monitoring real-time metal/dielectric interactions [J].Sensors and Actuators 13,2003,88:132-137.
  • 4定翔,余兴龙,耿俊清.表面等离子共振生物传感技术及仪器化的过去、现在与未来[J].现代科学仪器,2012,29(3):124-134. 被引量:3
  • 5Zynio S A,Samoylov A V,Surotseva E R,et al.Bimetallic layers increase sensitivity of affinity sensor based on surface plasmon resonance [J].Sensors,2002,2:62 -70.
  • 6Biow H O,YUAN Xiaocong,Tjin S C,et al.Optimised fihn thickness for maximum evanescent fild enhancement of a bimetallic film surface plasmon resonance biosensor [J].Sensors and Actuators B,2006,114:1028 - 1034.
  • 7Johansen K,Stalhert R,Lundstrom I,et al.Surface plasmon resonance:Instrumental resolution using photo diode array [J].Measurement Science and Technology,2000,11:1630- 1638.
  • 8Tao N J,Boussad S,Huang W L,et al.High resolution surface plasmon resonance spectroscopy [J].Review of Scientific Instrument,1999,70(12):4656 - 4600.
  • 9Ekgasit S,Thammacharoen C,YU Fang,et al.Evanescent field in surface plasmon resonance and surface plasmon field-enhanced fluorescence spectroscopies [J].Analytical Chemistry,2004,76(8):2210 - 2219.
  • 10Piliarik M,Homola J.Surface plasmon resonance(SPR)sensors,Approaching their limits? [J].Optics Express,2009,17:16505-16517.

二级参考文献16

  • 1耿俊清,章恩耀,余兴龙.成像式SPR传感测量中的图像处理方法[J].光学技术,2007,33(5):673-675. 被引量:2
  • 2GOPINATH S C B. Biosensing applications of surface plasmon resonance-based Biacore technology [ J ]. Sen- sors and Actuators B: Chemical, 2010, 150 ( 2 ) : 722-733.
  • 3PILLET F, ROMERA C, TR6VISIOL E, et al. Surface plasmon resonance imaging (SPRi) as an alternative technique for rapid and quantitative screening of small molecules, useful in drug discovery [ J ]. Sensors and Ac- tuators B: Chemical, 2011, 157(1): 304-309.
  • 4VANWIGGEREN G D, BYNUM M A, ERTEL J P, et al. A novel optical method providing for high-sensitivity and high-throughput biomolecular interaction analysis [J]. Sensors and Actuators B: Chemical, 2007, 127 (2) : 341-349.
  • 5O'BRIEN II M J, P6REZ-LUNA V H, BRUECK S R J, et al. A surface plasmon resonance array biosensor based on spectroscopic imaging [ J ]. Biosensors and Bioelec- tronics, 2001, 16(1-2): 97-108.
  • 6SZUNERITS S, BOUKHERROUB R. Electrochemical in- vestigation of gold/silica thin film interfaces for electro- chemical surface plasmon resonance studies[ J ]. Electro- chemistry Communications, 2006, 8 (3) : 439 A AA..
  • 7SHIN Y, KIM H M, JUNG Y, et al. A new palm-sized surface plasmon resonance (SPR) biosensor based on modulation of a light source by a rotating mirror[ J]. Sen- sors and Actuators B: Chemical, 2010, 150(1): 1-6.
  • 8GARET G N E A. Data analysis for optical sensors based on spectroscopy of surface plasmons [ J ]. Measurement Science and Technology, 2002, 13 (12) : 2038-2046.
  • 9ZHAN SH Y, WANG X P, LIU Y L. Fast centroid algo- rithm for determining the surface plasmon resonance angle using the fixed-boundary method [ J ]. Measurement Sci- ence and Technology, 2011, 22(2) : 25201.
  • 10YANG P, RAMAMOORTHY A, CHEN Z. Membrane orientation of MSI-78 measured by sum frequency genera- tion vibrational spectroscopy [ J ]. Langmuir, 2011, 27 (12) : 7760-7767.

共引文献3