摘要 空气流量传感器可以精确测量发动机进气量,发动机在进气管内的流动是流速变化较大的非稳态流动,需要流量传感器具有较快的动态响应特性。通过建立取样流道中的热固耦合模型,利用流体力学的方法,模拟计算动态响应特性,获得了流量传感器探头的温度场,利用阶跃脉冲模拟计算了传感器的动态响应特性,利用气道试验台进行动态响应特性的测试。热膜的热平衡需要一个自我调整的过程,所以,实测的动态响应速度低于计算模拟值。 Air flow sensor can accurately measure intake flow of engine, air flow in engine intake manifold is unsteady flow whose flow velocity changes remarkably,therefore, flow sensor should has faster dynamic response. A thermosetting coupling model of a hot-film sensor is established based on CFD which is used to simulate dynamic response characteristics, temperature field of the hot-film flow sensor probe is simulated, and in addition, dynamic response characteristics of sensor is simulated and calculated using step pulse, test dynamic response characteristics based on flow test equipment. Dynamic response speed is lower than the value of simulation, because heat balance of hot-film needs a self-regulation process.
出处 《传感器与微系统》 CSCD 北大核心 2014年第5期15-17,共3页 Transducer and Microsystem Technologies
关键词 流量传感器 响应 流体 传热 flow sensor response fluid heat transfer
  • 相关文献

参考文献6

二级参考文献19

  • 1Tien C L,Heat Trans,1994年,116卷,799页
  • 2Kastner L J,Engineering,1951年,9期,389页
  • 3史绍熙,学位论文,1949年
  • 4史绍熙,A Paper Presented at a Seminar at Manchester University,1949年
  • 5Shih S H,The Effect Side Boundaries Viscous Flow Throgh Rectangular Channels Large Widthdopth Ratio,1949年
  • 6司测研,Technical Information
  • 7山田制作所,层流形流量计使用说明
  • 8上海理工大学内燃机基础所,LCL系列气体层流流量计使用说明书,1996年
  • 9普朗特,流体力学概论,1984年
  • 10王伯年,机械工程学报,1981年,17卷,2期,85页

共引文献19

同被引文献8

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部